Commands
Chapter 4
WAAS G-III Reference Receiver User Manual Rev 1
61
Table 24: Message Type
Message Type
Allowed Trigger
AGCINFOB
ONCE, ONTIME
ALLSQMIB
ONNEW
ALLSQMQB
ONNEW
ALMANACB
ONCE, ONNEW
CARDSTATUSB
ONCE, ONTIME
CORRDATAB
ONCE, ONTIME
CORRLOCATIONB
ONCE, ONTIME, ONNEW
ETHSTATUSB
ONCE, ONTIME
EXCEPTIONDATAB
ONCE
FACTORYDATAB
ONCE, ONTIME
MEASUREMENTDATAB
ONCE, ONTIME
RANGEB
ONCE, ONTIME
RAWGPSSUBFRAMEWPB
ONNEW
RAWFRAMEDATAB
ONNEW
RAWWAASFRAMEWPB
ONNEW
RXCOMMANDSB
ONCE, ONTIME
SATPOSB
ONCE, ONTIME
SOFTLOADSTATUSB
ONCE, ONTIME, ONNEW
TIMESOLUTIONB
ONCE, ONTIME
VERSIONB
ONCE, ONTIME
Logs with an allowed trigger of ONNEW may also be logged with a trigger of ONCE. However,
only one log will be output, regardless of the number of related logs for each tracked signal. This
means that if 5 signals are tracked, only one of those signals will be reported for frame logs.
Although the LOG command is accepted in the Configuration and Maintenance states, some
logs (e.g. MEASUREMENTDATAB) are only output in the Operational state. If a LOG
command is provided for one of these logs in the Configuration state, the command is accepted
and saved but the log will not begin to be output until the receiver is transitioned to the
Operational state.