Data Logs
Chapter 5
WAAS G-III Reference Receiver User Manual Rev 1
101
variable
32-bit CRC
Hex
4
H+20 +
(#cards *
60) + 4 +
(#previous
fans * 4)
Field
Field Name
Description
Format # Bytes
Binary
Offset
Table 36: IOMaster Warning Status Word
Nibble
Bit #
Description
N
0
0
Reserved (0)
1
Reserved (0)
2
Reserved (0)
3
Reserved (0)
N
1
4
Reserved (0)
5
NVM test warning
6
Temperature monitor communications test warning
7
Voltage monitor communications test warning
N
2
8
CPU usage warning
9
Internal communication warning
10
External communication warning
11
Stack usage warning
N
3
12
Reserved (0)
13
Reserved (0)
14
Reserved (0)
15
Reserved (0)
N
4
16
Temperature warning test failed
17
Voltage warning test failed
18
Fans warning test failed
19
Reserved (0)
N
5
20
Reserved (0)
21
Reserved (0)
22
Reserved (0)
23
Reserved (0)
N
6
- N
7
24 - 31
Reserved (0)