26
WAAS G-III Reference Receiver User Manual Rev 1
Chapter 2
Installation
If the default Ethernet settings are compatible with your network, go to
Section 2.1.5 Connect the Ethernet
ports
on page 24.
If the default Ethernet setting are not compatible with your network, go to
Section 2.2.2 Connect to the
Maintenance port
on page 26.
2.2.2
Connect to the Maintenance port
To use the Maintenance port, the serial port settings of the computer you are using must match the following:
• RS-232C protocol
• 115200 bits per second (bps)
• No parity
• 8 data bits
• 1 stop bit
• No handshaking
• Echo off
After you have configured the serial port settings on your computer, connect a serial cable with a DB9
connector from the computer to the Maintenance port (J05) on the G-III Reference Receiver. Refer to
Table 54,
Port Specifications
on
Page 136
.
From the Maintenance port, you can configure the settings for the Ethernet ports. See
Section 2.2.3, Configure
the Ethernet Port Settings on Page 26
.
2.2.3
Configure the Ethernet Port Settings
From the computer connected to the Maintenance port, enter the following commands to configure the Ethernet
ports.
1. If you are configuring the
Data
port, skip to the next step.
If you are configuring the
Monitor
port, use the
ICOMCONFIG
command to set the virtual COM
port, UDP port and peer IP addresses.
See
Section 4.4.12, ICOMCONFIG on Page 57
for information about using the
ICOMCONFIG
command.
IP Addressing Mode
Static
IP Address
0.0.0.0
Netmask
0.0.0.0
Gateway
0.0.0.0
Table 6: Monitor port default settings
Setting
Value
You cannot change the port settings for the Maintenance port.