98
WAAS G-III Reference Receiver User Manual Rev 1
Chapter 5
Data Logs
5.5.5
CARDSTATUSB
This log contains status information for the IOMaster, all DSPC cards, the RF Carrier Card, all RF Daughter
Cards and the fans.
Output states
:
Configuration, Operational, Maintenance
Valid trigger
: ONCE,
ONTIME
Frequency
: When
requested
Message ID
: 4098
Header Format
:
G-III Log
There are a total of three entries for the RFCC to report all the necessary information.
Field
Field Name
Description
Format # Bytes
Binary
Offset
1
Header
G-III log header
H
0
2
State
Receiver operating state
0 = OFF
1 = CONFIGURATION
2 = OPERATIONAL
3 = MAINTENANCE
4 = BOOT
Ushort
2
H
3
Mode
Receiver operating mode
0 = NORMAL
1 = FAILED
Ushort
2
H+2
4
Atten setting
Software attenuator setting
Ulong
4
H+4
5
#hours
Total number of hours of power on since
manufacture of IOMaster card.
Ulong
4
H+8
6
DSPC Error Signal
Bit-field indicating the current state of all DSPC error
signals. The bit position corresponds to Card ID.
Ulong
4
H+12
7
#cards
Number of cards to follow.
Ulong
4
H+16
8
component
Component type
0 = UNKNOWN
1 = IOMASTER
2 = DSPC (Digital Signal Processing Card)
3 = RFCC (Radio Frequency Carrier Card)
4 = RFDC (Radio Frequency Daughter Card)
Enum
4
H+20
9
Slot ID
IOMaster = 7
DSPC = slot ID of DSPC
RFCC 1 (first RFCC values) = 4
RFCC 2 (second RFCC values) = 4
RFCC 3 (third RFCC values) = 4
RFDC = 4
Ushort
2
H+24