Commands
Chapter 4
WAAS G-III Reference Receiver User Manual Rev 1
65
4.4.16
PLLDYNAMIC
This command sets the low-pass filter bandwidth value. It also enables or disables the dynamic PLL tracking
and sets the parameters associated with dynamic PLL tracking.
The following restrictions apply to the
PLLDYNAMIC
command:
• The
highbw
value must be larger than or equal to the
lowbw
value or the command will be
rejected.
• The optional parameters are required fields when dynamic PLL is enabled (by specifying
enable
for the
setting
field).
• The locktime may not be reset to zero when the dynamic PLL is enabled through
PLLDYNAMIC
command.
Valid States
: Configuration,
Operational
Valid Modes
: Normal
Acceptable Ports
: Data
Syntax:
PLLDYNAMIC signal setting lowbw [highbw cno PLLerror timethreshold]
Example:
PLLDYNAMIC L1ca TRUE 3 10 30 0.15 2000
PLLDYNAMIC L5geo FALSE 1
The
PLLDYNAMIC
command can fundamentally change the way that the receiver operates. Do
not alter the default settings unless you are confident that you understand the consequences.
The channels are not reassigned when this command is issued. They may continue to track when
the command is applied. This is different than the G-II Reference Receiver PLLBW command,
which did reassign the channels, causing them to lose lock and resetting the lock time for all
tracking satellites to zero.
Field
Field Name
Description
Range
Precision
1
signal
Signal type
L1ca
L1geo
L1C
L2py
L2C
L5gps
L5geo
N/A
2
setting
Enter TRUE to enable dynamic PLL,
Enter FALSE to disable dynamic PLL.
When this field set to FALSE, the fields
marked as optional are not necessary and
are ignored if specified.
When this field set to TRUE, all of the fields
are mandatory.
TRUE
FALSE
N/A