Chapter 4
Commands
4.4.26
SOFTLOADSREC
This command sends an S-Record format data block to a RAM buffer on the G-III Reference Receiver.
The data block can contain a single S-Record, or multiple S-Records packaged together.
Valid States
:
Maintenance
Valid Modes
:
Normal, Failed
Acceptable Ports
:
Data
Syntax:
SOFTLOADSREC s-records
Examples:
SOFTLOADSREC S31D00000048000000000000000000000000000000000000000000000000
9A
SOFTLOADSREC S0~T~APPS31D0000000006E0A6E10100000028000000280008000000001C
E001001C03S31D0000001830000000582E5C009F5856AA2A5AD03501000000FEFFFFFF3C
All S-Records in the data block must be valid and complete.
Field
Field Name
Description
Range
Precision
1
s-records
S-Record Entries
String
2 to 8000 bytes
N/A