Commands
Chapter 4
WAAS G-III Reference Receiver User Manual Rev 1
67
4.4.17
PULSEBLANKING
This command enables or disables digital pulse blanking. The sensitivity of the digital pulse blanking may be
adjusted using the threshold field. When the pulse blanking extension time is non-zero, the receiver will
continue to blank the signal for the specified extension time.
Valid States
: Configuration,
Operational
Valid Modes
: Normal
Acceptable Ports
: Data
Syntax:
PULSEBLANKING frequency threshold exttime
Example:
PULSEBLANKING L2 0 2
PULSEBLANKING L5 120 4
The
PULSEBLANKING
command can fundamentally change the way that the receiver operates.
Do not alter the default settings unless you are confident that you understand the consequences.
Field
Field Name
Description
Range
Precision
1
frequency
Specifies which frequency type to apply the
command to.
L1
L2
L5
N/A
2
threshold
Pulse Blanking threshold
To turn off pulseblanking, set the threshold value to 0.
0-127
Int
3
exttime
Pulse blanking extension time (μs)
0-10
Int