Performing RAID maintenance
Standard 1.0
230
CallPilot
10
Repeat steps 6 to 9 for System Pack B (if applicable), and then for
System Pack C (if applicable).
Note:
There is no need to press Esc after you finish creating the last
System Pack. The last System Pack is automatically closed, and the
cursor control moves to the Pack Definition menu.
11
Select Arrange Pack, and then press Enter.
12
Select a drive from System Pack A (for example, A-0), and then press
Enter.
Result:
The System Pack is arranged.
13
Repeat step 12 for a drive in System Packs B and C (if applicable).
Result:
When all System Packs are arranged, the system returns you to
the New Configuration menu.
14
Select Define System Drive, and then press Enter.
Result:
The System Drive Definition menu appears.
15
Select Create System Drive, and then press Enter.
Result:
The system prompts you to choose which RAID Level to use.
16
Select RAID 1, and then press Enter.
Result:
The system prompts you to enter the size of the first system
pack.
17
Enter the size of the system pack as specified in “RAID system pack
sizing” on page 227, and then press Enter.
Result:
The system prompts you to confirm that you want to create this
system drive.
18
Select Yes.
Result:
The system pack is created and listed with its settings.
19
Repeat steps 16 to 18 for the remaining system packs. When you finish,
press Esc to exit to the Create System Drive window.
Result:
The system packs are defined.
Содержание CallPilot 1001rp
Страница 2: ...P0949455...
Страница 6: ...vi CallPilot Publication history Standard 1 0...
Страница 38: ...Troubleshooting your CallPilot system Standard 1 0 38 CallPilot...
Страница 62: ...Using Windows NT online diagnostic tools Standard 1 0 62 CallPilot...
Страница 74: ...Using serial port diagnostic tools Standard 1 0 74 CallPilot...
Страница 88: ...Using CallPilot Manager to monitor hardware Standard 1 0 88 CallPilot...
Страница 114: ...Using CallPilot Manager to monitor hardware Standard 1 0 114 CallPilot...
Страница 150: ...Replacing basic chassis components Standard 1 0 150 CallPilot...
Страница 168: ...Replacing a hard drive tape drive CD ROM drive or floppy drive Standard 1 0 168 CallPilot...
Страница 178: ...Performing RAID maintenance Standard 1 0 178 CallPilot...
Страница 260: ...Performing RAID maintenance Standard 1 0 260 CallPilot...
Страница 274: ...Replacing or adding voice processing boards Standard 1 0 274 CallPilot...
Страница 280: ...Replacing the video card Standard 1 0 280 CallPilot...
Страница 292: ...Replacing the network cards Standard 1 0 292 CallPilot...
Страница 320: ...Maintaining the Pentium II SBC card Standard 1 0 320 CallPilot Pentium II SBC...
Страница 326: ...Maintaining the Pentium II SBC card Standard 1 0 326 CallPilot 22 Reconnect the serial port cables EMI gasket...
Страница 348: ...Maintaining the Pentium III SBC card Standard 1 0 348 CallPilot...
Страница 367: ......