Calibration and Adjustment
5-17
5.12 Initializing the Digital Gauges
The S2-900 Series Dispensing System is equipped with Cooling/Coaxial, Valve and Fluid Pressure Digital
Gauges. If the system is configured with the optional Electronic Pressure Control Utility, the digital gauges
will not be present.
To initialize the digital gauge:
1.
Make sure the air pressure to the pressure gauge is OFF by turning the appropriate regulator
knob counterclockwise until it stops (Figure 1-7).
2.
To configure the gauge, press and hold down the
SET
button for at least two (2) seconds
(Figure 5-18).
3.
Select the Measuring Unit by pressing the
Up
button or
Down
button until the desired
measuring unit is displayed and then press
SET
.
Available units are kPa or MPa (PA), kgf/cm2 (GF), bar (bAr), and psi (PSi).
4.
Verify the Output 1 type is set on the normally open (1no) setting. If it is not displayed,
press the Up or Down button until 1no is displayed and then press
SET
.
NOTE
The output function of the digital gauge is not used on your dispensing system.
5.
Verify the Response Time is set at 192 ms. If it is not displayed, press the
Up
or
Down
button until 192 is displayed.
6.
Verify the Setting Mode is set on the manual setting (nAn). If the manual setting is not
displayed, press the
Up
or
Down
button until nAn is displayed and then press
SET
.
The gauge will now be in the pressure-measuring mode.
7.
Zero the gauge by holding down both arrow buttons simultaneously until zeros (00.0) are
displayed on the screen.
8.
Set the pressure to the desired level for your application by turning the knob on the pressure
regulator knob clockwise until the correct pressure is displayed on the screen.
TIP
To ensure accurate pressure measurement, allow the gauge to warm up for 20 to 30
minutes before adjusting pressure level.
35.4
OUT 1
SET
SMC
MPa
PRESSURE
Item
Description
Item
Description
1
LED Display
4
Set Button
2
Switch Output Indicator
5
Down Button
3
Up Button
Figure 5-18 Initializing the Digital Gauge
1
2
3
4
5
Содержание Spectrum II S2-900 C Series
Страница 2: ......
Страница 34: ...1 20 Introduction 1 11 7 Rear View Figure 1 8A S2 900 Rear View 30A Power Manager shown 1 2 3 4 5 7 6...
Страница 36: ...1 22 Introduction 1 11 8 Rear View Open Figure 1 9A S2 900 Rear View Open 1 2 3 4...
Страница 40: ......
Страница 124: ......
Страница 157: ...Calibration and Adjustment 5 33 Figure 5 38 Dispense Lift Table Controls...
Страница 159: ...Calibration and Adjustment 5 35 Figure 5 40 Beacon Configuration Window...
Страница 186: ......
Страница 197: ...Troubleshooting 7 11 Figure 7 1 Scale Setup Menu Figure 7 2 Scale Error Message...
Страница 200: ......
Страница 215: ...Parts Replacement 8 15 Figure 8 11 Replacing a Panel Mounted Fuse...
Страница 218: ......
Страница 223: ...Specifications 9 5 Top View mm Back View mm Figure 9 2 S2 900 System Dimensions 2 of 2...
Страница 225: ...Specifications 9 7 Top View mm Back View mm Figure 9 4 S2 9XXC System Dimensions 2 of 2...
Страница 228: ...A 2 Appendix A Material Safety Information A 2 1 Multemps PS NO 2...
Страница 229: ...Appendix A Material Safety Information A 3...
Страница 230: ...A 4 Appendix A Material Safety Information...
Страница 231: ...Appendix A Material Safety Information A 5...
Страница 232: ...A 6 Appendix A Material Safety Information...
Страница 233: ...Appendix A Material Safety Information A 7...
Страница 234: ...A 8 Appendix A Material Safety Information A 2 2 Moly Graph Extreme Pressure Multi Purpose Grease...
Страница 235: ...Appendix A Material Safety Information A 9...
Страница 236: ...A 10 Appendix A Material Safety Information...
Страница 237: ...Appendix A Material Safety Information A 11...
Страница 238: ...A 12 Appendix A Material Safety Information...
Страница 239: ...Appendix A Material Safety Information A 13...
Страница 240: ...A 14 Appendix A Material Safety Information...
Страница 246: ......
Страница 252: ......
Страница 258: ......