Powder Pilot
™ HD
P/No.7192721_02
Page | 37
Spectrum HD CONFIGURATION SECTION 1
Pushing the button
on the Spectrum HD control screen will display the configuration screens
described below.
Note:
configuration shall only be done by authorized and trained personnel!
Exit screen Next screen
1 2 3 4 5 6
1
–
hopper empty assist air time out
–
Time to switch on the assist air after the low level probe gets free
of powder when emptying the hopper.
2
–
hopper empty time out
–
Count down time after the low level probe gets free of powder when
emptying the hopper. After the countdown the OK button will be displayed to move on to the next step.
3
–
purge to hopper dump valve delay
–
time to delay the opening of the dump valve while cleaning the
hopper.
4
–
hopper banger count
–
amount of beats to the hopper from the shaking device while emptying to the.
box.
5
–
level probe off delay
–
The time required for the mid level probe to be registered as off.
6
–
level probe on delay
–
The time required for the mid level probe to be registered as on.
Содержание PowderPilot HD
Страница 2: ...Powder Pilot HD P N 7192721_02 Page 2...
Страница 3: ...Powder Pilot HD P N 7192721_02 Page 3...