Powder Pilot
™
HD
P/No.7192721_02
Page | 17
Screen elements
1 2 3 4 5 6 7
8 9 10 11
1
–
program control
–
This data entry field has two functions It shows the program that is currently
running in the system When pressed, it also allows the operator to create, delete, select or change
programs. These procedures are described in detail in a subsequent section of this manual.
2
–
fan status
–
This symbols’ colour indicates the current state of the extract fan
.
These are as follows:-
Grey - The fan is stopped
Green - The fan is running
Flashing Red - The fan is in fault
3
–
alarm symbols
–
These symbols are flashing in case of any alarm occurs on the system The
corresponding message can be seen in the alarm summary list (J).
4
–
gun to part distance
–
This data entry sets the distance the gun will position itself away from the
product regardless of the product size There is one entry for the mover on the left side of the booth
and one for the mover on the right side.
5
–
conveyor status / speed
–
This displays the condition of the conveyor When in static grey, the
conveyor is stopped When flashing two tone green, the conveyor is running A component will also
appear hanging from the conveyor when the booth has product within it The number displays the
conveyor speed in metres / minute for indication purposes only .
6
–
production data
–
These displays from top to bottom are:-
Shift product count
–
This is the total number of products sprayed since the last reset
Total product count
–
This is the total number of products sprayed since commission
Shift production hours
–
This is the total number of hours the system has sprayed for with the
conveyor running since the last reset
Total production hours
–
This is the total number of hours the system has sprayed for with the
conveyor running since commission
Содержание PowderPilot HD
Страница 2: ...Powder Pilot HD P N 7192721_02 Page 2...
Страница 3: ...Powder Pilot HD P N 7192721_02 Page 3...