7
–
reset production data
–
this button will reset the shift counters mentioned above
To reset the shift counters, touch the counters and the button will appear Pressing this button will reset
them and the button will then automatically disappear again
8
–
gun fault status
–
This button will display the gun fault screen where a more detailed fault code
can be obtained for any gun
Exit screen
Reset errors
1 2
1
–
KV node errors for Gun 5
–
fault occurred on KV side of gun number 5
2
–
Pump node errors
for Gun 5
–
fault occurred on KV side of gun number 5
If any of these “LED
-
symbols” is drawn as red light, try to reset the fault by touching the reset button in
the top right corner of the screen
If the problem persists, contact your Nordson representative for information on these codes
The fault codes indicated are explained as follows-
KV card faults-
Pump card faults-
E1
uA has not reached alarm set point. This is used with Tribo
guns where a low charge uA value is set for alarm
F1
Communication. The pump card has lost
communication with the gateway
E2
Fold back. The gun is trying to draw more than 100uA
F2
No 24V. The 24V supply to the pump system
has been lost
E3
Feedback. The uA feedback wire is broken in the gun
cable
F3
General alarm. On for any other fault that
cannot be detailed in this list
E4
Open circuit. The voltage multiplier is open circuit
F4
Reserved for future use.
E5
Short circuit. The voltage multiplier is short circuit
F5
Powder air is higher than set point
E6
Hardware. The KV card itself has a fault
F6
Pattern air is higher than set point
E7
General alarm. On for any other fault that cannot be
detailed in this list
F7
Powder air is lower than set point
E8
No 24V. The 24V supply to the KV system has been lost
F8
Pattern air is lower than set point