Powder Pilot
™HD
P/No.7192721_02
Page | 35
Spectrum HD screen elements
1
–
Powder level monitor
–
the cut out in the hopper is shown in 4 steps representing the actual powder
level inside:
Powder level high,
hopper full
Powder level medium,
this is the working level which the system maintains using the virgin
pump only. The recycle pump runs all time unless switched off or powder level is on high
level.
Powder level low,
this is the minimum level for the pumps to work properly When the
powder level drops below this, an alarm is raised to inform the operator about this issue.
Hopper empty,
no level probe actually detects powder This can happen right after a colour
change or when the system has just been started up.
In all other situations this is an Error due to lack of powder .
Operator interaction is urgently required.
2
–
Virgin HDLV-transfer pump
–
this shows the status of the virgin pump and allows the operator to
start or stop the pump by touching the pump symbol.
Pump running
Pump stopped
3
–
Reclaim HDLV-transfer pump
–
this shows the status of the reclaim pump as shown above and
allows the operator to start or stop the pump by touching the pump symbol.