![Nordson Encore Select HD Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/nordson/encore-select-hd/encore-select-hd_customer-product-manual_1704463039.webp)
© 2022 Nordson Corporation
6-5
Electrode Assembly Resistance Test
Use a megohm meter to measure the resistance of the electrode assembly from the
contact ring on the back to the antenna wire in the front. The resistance should be 19-21
megohms. If the resistance is out of this range replace the electrode assembly.
Figure 6-2 Electrode Assembly Resistance Test
Cable Continuity Test
Use a standard ohmmeter to check the gun cables and harness for continuity.
Gun Cable Receptacle Harness
This harness is used on both the bar-mount and tube-mount spray guns to connect the
power supply (voltage multiplier) to the extension cable (tube-mount spray gun) or gun
cable.
J2 (FACE VIEW)
J2-1
(BROWN)
J2-4 (BLACK)
J2-3 (BLUE)
J2-2
(WHITE)
BROWN
BLUE
BLACK
WHITE
OSCILLATOR
COMMON
FEEDBACK
CHASSIS GND
CABLE GND
WIRING DIAGRAM
J3-1 (BROWN)
J3-2 (BLUE)
J3-3 (WHITE)
J3 (FACE VIEW)
Figure 6-3 Gun Receptacle Harness