© 2022 Nordson Corporation
4-5
Changing Optional Deflectors or Conical Nozzles
WARNING:
Release the spray gun trigger, turn off the interface, and ground the
electrode before performing this procedure. Failure to observe this warning could result
in a severe electrical shock.
NOTE:
The tapered flat spray electrode holder shipped with the spray gun will need to
be changed in order to accept the conical nozzles and deflectors. The conical nozzle
kit shipped with the spray gun is required for this conversion. See page 4-4 for
conversion instructions.
1.
Purge the spray gun and turn off the interface to prevent accidentally triggering the
spray gun on.
2.
Gently pull the deflector (4) off the electrode holder (1A). If only changing the
deflector, install the new one on the electrode holder, being careful not to bend the
electrode wire.
3. To change the entire nozzle, unscrew the nozzle nut (3) counterclockwise.
4.
Pull the conical nozzle (2) off the electrode assembly (1).
NOTE:
If the electrode assembly comes out of the powder outlet tube, re-install it.
5. Install a new conical nozzle (2) on the electrode assembly. The nozzle is keyed to the
electrode assembly (1).
6.
Screw the nozzle nut (3) onto the spray gun body clockwise until finger-tight.
7.
Install a new deflector (4) on the electrode assembly. Do not bend the electrode wire.
1
1A
2
3
4
Figure 4-3 Changing a Conical Nozzle
Содержание Encore Select HD
Страница 6: ...2022 Nordson Corporation 1620445 03 ii Change Record...
Страница 10: ...2022 Nordson Corporation 1620445 03 1 4 Safety...
Страница 14: ...2022 Nordson Corporation 1620445 03 2 4 Overview...
Страница 20: ...2022 Nordson Corporation 1620445 03 3 6 Setup...
Страница 34: ...2022 Nordson Corporation 1620445 03 5 6 Repair...