![Nordson Encore Select HD Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/nordson/encore-select-hd/encore-select-hd_customer-product-manual_1704463018.webp)
© 2022 Nordson Corporation
3-4
Encore Controller Interface Configuration Settings
NOTE:
Refer to manual 1604870,
Encore HD and XT Manual Powder Spray System
Controller
, for more information about the controller.
See Figure 3-3
. Each Encore controller interface (2) must be configured with the function
codes set to the values listed in Table 3-1 for each spray gun in a dual robot spray gun
system.
Table 3-1 Encore Controller Function Code Values
Function Code
Spray Gun 1
Spray Gun 2
F00
02 (Robot)
02 (Robot)
F17
10 (Presets)
10 (Presets)
F18
01 (HDLV)
01 (HDLV)
F19
01 (EXT)
01 (EXT)
F20
01 (GUN)
02 (GUN)
iFlow
®
PCA Configuration Settings
The following switch settings and CAN network jumper settings must be set to the values
listed in Table 3-2 for each of the spray guns in a dual robot spray gun system.
Table 3-2 Encore Controller Function Code Values
Robot Spray Gun
Address Switch Value
Spray Gun 1
SW2=1
Spray Gun 2
SW2=2
1. See Figure 3-3. Access the iFlow PCA inside the Encore HD pump control unit (7).
2. See Figure 3-4. The address switch SW2 must be set to the spray gun number that it
is supplying.
3. If the Encore HD pump control unit (7) is connected to the Nordson CAN network on
the drop, then the network terminator on JP1 must be removed on each of the pump
control units.
NOTE:
Each drop on the CAN network is limited to 6 m (20 ft) maximum.
Содержание Encore Select HD
Страница 6: ...2022 Nordson Corporation 1620445 03 ii Change Record...
Страница 10: ...2022 Nordson Corporation 1620445 03 1 4 Safety...
Страница 14: ...2022 Nordson Corporation 1620445 03 2 4 Overview...
Страница 20: ...2022 Nordson Corporation 1620445 03 3 6 Setup...
Страница 34: ...2022 Nordson Corporation 1620445 03 5 6 Repair...