Parts Replacement
9-9
9.9
Replacing the Height Sensor Probe
To replace the Height Sensor Probe:
1.
Remove all valve clamps attached to the Z-head (
16H
Figure 9-4).
2.
Remove the Z-head top cover.
3.
Remove the front valve panel.
4.
Unhook the two springs from the upper spring bracket.
5.
Remove the Z-plate.
6.
Dismount the height sensor assembly from the Z-carriage.
17H
Figure 9-4A Removing the Z-head Top Cover
and Front Valve Panel
18H
Figure 9-4B Removing the Z-plate
Item Description Item Description
1
Z-head Cover and Front Valve Panel
4
Z-plate
2
Valve Clamps
5
Height Sensor Assembly
3
Upper Bracket Springs
6
Z-carriage
Figure 9-4 Removing the Z-Head Panels
1
2
3
4
5
6