5-4
Calibration and Adjustment
3.
Click on
Calibrate
.
!
The Calibration Window (Figure 5-3) opens.
Figure 5-3 FmXP Calibration Window
4.
Position the camera over a fiducial and adjust the light level to obtain a good image contrast.
5.
If the image is not in focus, focus the camera as described in
6.
Click on
Next
.
7.
Verify that the fiducial image is centered and click on
Next
.
!
The Vision System will take a snap image of the fiducial.
8.
If the fiducial is acceptable, select
Next
. If not, select
Prev
and define a new fiducial.
"
NOTE
The fiducial should fit inside the green square on the camera image.
9.
After the camera calibration sequence is complete, verify that the X and Y values are
relatively close to each other. If there is a large difference, repeat the calibration process and
define a new fiducial.
10.
If the results are satisfactory, select
Done
to save the calibration results.
"
NOTE
Machine Offsets must be performed after calibrating the camera. For more information,
refer to the
FmXP User Guide
or Online Help.
Содержание Asymtek Spectrum S-920
Страница 1: ...Spectrum Series S 920 Dispensing System Installation Operations Maintenance Manual P N 7212417 Rev A...
Страница 2: ......
Страница 4: ......
Страница 30: ...1 14 Introduction 1 10 5 Rear View Figure 1 7A Rear View 2 3 4 1 5...
Страница 124: ......
Страница 172: ...7 12 Maintenance Figure 7 7 Lubricating the X Axis Linear Guides Figure 7 8 Lubricating Y Axis Linear Guides...
Страница 185: ...Troubleshooting 8 11 Figure 8 3 FmXP Scale Setup Menu Figure 8 4 Scale Error Message...
Страница 190: ......
Страница 204: ......
Страница 208: ......
Страница 210: ......
Страница 220: ......
Страница 222: ......
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 234: ......