5-10
Calibration and Adjustment
5.10 Adjusting the Height Sensor Probe
The Height Sensor Probe must be adjusted each time a different type of dispensing valve or a different
length of needle is installed.
To adjust the Height Sensor Probe:
1.
Power down the system as described in
2.
Manually move the dispensing head down.
3.
Loosen the Height Sensor Probe locking screw at the back of the Z-axis plate.
See Figure 5-12.
4.
Move the probe to the desired location (approximately 10 mm below the needle tip in the
gear down position).
5.
Tighten the height sensor locking screw. Do not over-tighten.
Item Description
1
Z-Axis Plate (Front View)
2
Z-Axis Plate (Rear View)
3
Height Sensor Locking Screw
4
Height Sensor Probe
Figure 5-12 Adjusting the Height Sensor Probe
"
NOTE
For additional information on dispensing valve-to-height sensor offsets, see
3
4
1
2
Содержание Asymtek Spectrum S-920
Страница 1: ...Spectrum Series S 920 Dispensing System Installation Operations Maintenance Manual P N 7212417 Rev A...
Страница 2: ......
Страница 4: ......
Страница 30: ...1 14 Introduction 1 10 5 Rear View Figure 1 7A Rear View 2 3 4 1 5...
Страница 124: ......
Страница 172: ...7 12 Maintenance Figure 7 7 Lubricating the X Axis Linear Guides Figure 7 8 Lubricating Y Axis Linear Guides...
Страница 185: ...Troubleshooting 8 11 Figure 8 3 FmXP Scale Setup Menu Figure 8 4 Scale Error Message...
Страница 190: ......
Страница 204: ......
Страница 208: ......
Страница 210: ......
Страница 220: ......
Страница 222: ......
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 234: ......