Parameter
Factory Default Setting
Language
English
Adjustable range
v (full possibility of variation for manual entry)
Row 1
IN1; Cycl.Count 1; Block Count 1
Stop
0 (Emergency OFF is deactivated)
NOTE:
When Stop is set to 0, the device can be used to experimentally dispense
without a 24 V signal; for this function, 24 V must be on pin 17 for IN_FAULT_PLC.
Code (password)
- - - - - - (6 spaces)
NOTE:
6 zeros (0) in the control program are equivalent to 6 spaces (6 presses) of
the Enter key on the PICO controller.
CAN baud rate
125 kBit/s
CAN address
63
All other parameters
0
Program Cycles, Program Files, and Factory Settings (continued)
Factory Settings
After a factory reset, the PICO controller returns to the following factory default settings.
PICO Controller 2+2-XCH-V2
35
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.