Program example 3
Example includes only channel 1:
All of the lines are linked to form an infinite loop without delays (connecting time=0) and there is no external
continuous signal (ext.puls = 0). The infinite loop can be started from any line (with IN1 to IN9) and runs indefinitely;
the dispensing sequence is stopped with IN_STOP; all of the parameters can be modified with the adjustable range
= v within the full scope via the control unit
[Device]
PDA2+2
[HW Revision] 2.2
[SW Revision] 2.2
[Filename]
PDA2_example_03.txt
[Description]
This is a PDA2+2 generated file.
(NOTE: Any text can be added as a comment; square brackets are not permitted.)
[Data]
Code 000000
Valve-no.
Ventil-Nr. 1
container
limit
adjustable range
temperature
stop
Gebinde, voll Grenzrestmenge
Einstellbereich
Temperatur
Stop
Delay-Time
1000.00
100.00
v
35.0
1
0.00
line
dosing time
pausetime
number of runs IN
connected line connecting time blocknumber dosing value ext.puls
Zeile
Dosierzeit
Pausenzeit
Pulsanzahl
IN
V-Zeile
Verz.-Zeit
Blockanzahl Menge ext.Dauers.
1
0.05
10.00
1
1 2
0
1
0.05
0
2
0.10
10.00
1
2 3
0
1
0.10
0
3
0.20
10.00
1
3 4
0
1
0.20
0
4
0.40
10.00
1
4 5
0
1
0.40
0
5
0.80
10.00
1
5 6
0
1
0.80
0
6
1.60
10.00
1
6 7
0
1
1.60
0
7
3.20
10.00
1
7 8
0
1
3.20
0
8
6.40
10.00
1
8 9
0
1
6.40
0
9
12.80
10.00
1
9 1
0
1
12.80
0
[Data End]