Command and
Command Code
Type of CAN
Telegram
Part of CAN
Telegram
Structure of the
Telegram Part
Encoded Information
Start valve command
code
Request
(from master to
slave)
Identifier
11 bits binary
Sender: 0
Command code: 5
Slave address:
5 decimal 0101 binary
Data field
Data bytes
1 and 2
(2 x 8 bits)
Valve no.
Line no.
Response
(from slave to
master)
Identifier
11 bits binary
Sender: 1
Command code: 5
Slave address:
Data field
Error byte
0, 1, 2 or 3
(1 x 8 bits)
0 = No error
1 = Valve not in CAN mode
2 = Dispensing already active
3 = Stop activated
Start valve command
code
Request
(from master to
slave)
Identifier
11 bits binary
Sender: 0
Command code: 6
Slave address:
6 decimal
0110 binary
Data field
Data byte 1
(1 x 8 bits)
Valve no.
Response
(from slave to
master)
Identifier
11 bits binary
Sender: 1
Command code: 6
Slave address:
Data field
Error byte
0, 1, 2 or 3
(1 x 8 bits)
0 = No error
1 = Valve not in CAN mode
2 = Dispensing not active
3 = Internal communication error
Command List for CAN Bus Communication
Data Communication via CAN Bus (continued)
PICO Controller 2+2-XCH-V2
23
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.