PICO Controller Menu Schematic (continued)
Using Manual Operation to Test and Adjust Dispensing Parameters
1. Select Manual Operation > Valve X > Start (by pressing the Enter key) to manually start the dispensing process
for the active valve using the dispensing parameters of the activated line.
2. As the dispensing process runs, carefully adjust the dispensing parameters.
NOTE:
Changed values are applied immediately, allowing fine adjustments during the dispensing process. However,
to ensure that values are saved properly (in EEPROM), confirm each adjustment value by pressing the Enter key.
Request, if interface
was set to the previous
mode (Active or
CAN) before manual
operation
Dosing Parameters
Manual Operation
Automatic Mode
Level Control
Process Data
Manual Operation
Valve 1, Row
MANUAL OPERATION
Pulse Time:
Cycle:
Cycl. Count:
Temperature:
Ext. Puls:
Activation: IN1
Linkage: Z0
Delay: 0.000s
Block Count: 1
DosingValue: 0.00mg
Stop: 0
(Delay-Time: 100.00ms)
ESC
Enter
Valve
ESC
ESC
ESC
ESC
ESC
ESC
ESC
Enter
Enter
Enter
Enter
Enter
Enter
ESC
Manual Operation
Valve 1, Row
Manual Operation
Valve 1, Row
Manual Operation
Valve 1, Row
Manual Operation
Valve 1, Row
Dosing Parameters
Manual Operation
Automatic Mode
Level Control
Process Data
Automatic Mode
Valve 1:
Valve 2:
Valve 3:
Valve 4:
active
active
If an expansion card is installed,
the display shows the setting for
Valves 3 and 4.
Delay-Time is displayed
only if Cycle = Variable
Password code
may be required
Start
Enter
Enter
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Menu
Enter
PICO Controller 2+2-XCH-V2
30
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.