Specifications (continued)
Output Signals / Channels
Pulse-pause outputs
Electrical 24 V impulses to control dispensing sequences
System ready
0 V = not ready, 24 V = ready
End of pulse sequence
24 V pulse, duration 100 ms
Temp. dispensing fluid
24 V = normal, 0 V = temperature exceeded
Dispensing sequence fault
24 V = normal, 0 V = dispensing sequence fault (limit reached upon level check or faulty / missing
PICO
Toµch
controller)
Analog output
Temperature (0–5 V or 0–10 V can be configured) setpoint for the fluid
Output load
Per pulse output: max. 2 W (80 mA)
Per analog output: max. 10 mA
Per other output: max. 0.5 W (20 mA)
Standards
• The PICO controller is intended to be operated with 24 VDC and complies with the EMC guideline 2004/108/EG.
• The unit has the CE mark of conformity.
• The unit was inspected pursuant to the environmental testing method IEC 68.
PICO Controller 2+2-XCH-V2