38
7. Select the
Upper Limit
entry box and enter the required value (up to 2 decimal places i.e. 4.15).
This is the Torque Upper Limit as a percentage of the Target value.
8. Select the
Lower Limit
entry box and enter the required value (up to 2 decimal places i.e. 3.85).
This is the Torque Lower Limit as a percentage of the Target value.
9. Select the desired
Direction
of operation for limits.
10. Select the
Number of Readings
entry box and enter the value if required.
This value defines the number of tests to be taken for the Target value.
This is termed “# of Tests” on the T-Box XL™.
11. Select the
Tool
Stop
entry box if required and enter the required value.
Tool Stop is used to provide a stop signal for an external pneumatic, hydraulic or electric tool.
NOTE:
This is intended for use with PneuTorques so the ‘Lower limit’ does not have to be used as
a stop signal.
12. Select the
Internal
Snug
Torque
Trigger
tick box if required.
Enabling (Ticking) this option allows the user to define a Torque value at which the Angle starts reading
i.e. Torque followed by Angle.
13. Select the
Snug
Torque
entry box and enter the required value.
This will be greyed out if ‘Internal Snug Torque Trigger’ has not been ticked.
14. Select
Angle
Limits?
Tick box if required.
Select direction of operation for
Angle limits
.
15. Select
Angle
Target
entry box and enter the required value. This value is in degrees.
16. Select the
Upper
entry box and enter the required value.
This is the Angle Upper Limit value in degrees.
17. Select the
Lower
entry box and enter the required value.
This is the Angle Lower Limit value in degrees.
18. Select the
Next Target
drop down and select the required Target from the list.
19. Select the ‘
ISO Timing
’ tick box to enable the 80% to 100% timing indicators associated with ISO
6789:2017
20. Select
OK
to save the Target in TDMS.
This Target will be sent to a T-Box XL™ when next synchronizing with TDMS.
Содержание T-Box 43236
Страница 2: ......
Страница 47: ...45 4 Select Yes No or Cancel...
Страница 60: ...58 If the measurement system and temperature comply with ISO 6789 2 2017 the certificate will be generated...
Страница 79: ...77 Load Tools File 1 Select Options then select Load Tools File 2 Browse to the Tools txt file then select Open...