7
Angle Mode
NOTE:
Do not apply torque while torque and angle are zeroing otherwise torque zero offset will be
incorrect and wrench will indicate an angle reading when torque is released. If this occurs,
re-zero wrench by momentarily pressing POWER
button with wrench setting on a
stable surface with no torque applied.
1.
Angle Zero
If "ANGLE ZERO REQ" message is displayed, wait 2 seconds for automatic angle zeroing sequence
before applying torque or moving wrench.
2.
Set target
Use
UP
/DOWN
buttons to change target ANGLE value.
3.
Apply Torque and Rotate Wrench
Grasp centre of handle, (DO NOT pull on battery end-cap) and slowly apply torque to fastener and
rotate wrench at a moderate consistent speed until progress lights display green and a ½ second
audible alert and handle vibration alerts user to stop.
4.
Release torque
Note alternating peak TORQUE and ANGLE readings flashing on LCD display for 10 seconds. Pressing
BACKLIGHT
button while peak angle is flashing will continue to display value until button is
released. Momentarily press
UP
/DOWN , ENTER
or
UNITS
U
button to immediately return to
target ANGLE screen. Reapplying torque (ratcheting) before target screen is displayed will continue
ANGLE accumulation as wrench is rotated.
5.
Recall Peak ANGLE Reading
To recall last peak ANGLE measurement, press and hold
BACKLIGHT
button for approximately 3
seconds. Peak TORQUE and ANGLE will be displayed alternately for 10 seconds
.
Mode Cycle Count
ProTronic
®
mode cycle count feature is used to indicate number of times
wrench has reached target torque in torque measurement mode or target
angle in angle measurement mode.
Torque and Angle Mode Cycle Counting
1.
Numerical counter located in top right of target torque or target angle screen will increase after each
torque or angle cycle if applied torque or angle has reached target value.
2.
When toggling between torque mode and angle mode using
ENTER
button or if target is changed,
numerical counter will reset back to 00. Counter WILL NOT reset when re-zeroing, on menu entry/exit or
power down.
3.
Memory icon will turn on indicating at least one torque or angle cycle data has been stored in memory.
Main Menu
Main menu displays wrench operational information.
1.
From target torque or angle screen, press and hold
ENTER
button for 3 seconds.
2.
Use
UP
/DOWN
buttons to highlight menu selection then press
ENTER
button.