13
Adding a Torque Pre-set
1. From target torque screen, select units of measure.
2. Press and hold
UNITS
U
button
for 3 seconds.
3. ADD PRE-SET confirmation screen is displayed. Highlight
YES
menu selection using
UP
/DOWN
buttons then press
ENTER
button
.
NO
menu selection returns to main menu without adding a PSET.
4. MINIMUM TORQUE is target value at which green progress lights, audible alert and vibrator turn on.
Initial MINIMUM TORQUE value is value from target torque screen. MINIMUM TORQUE can be set to
any value within wrench torque range by pressing
UP
/DOWN
buttons. Once desired target torque
value has been set, press
ENTER
button
.
5. MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which red
progress lights turn on. Initial MAXIMUM TORQUE value will be MINIMUM TORQUE plus 4%. Maximum
torque value can be set greater than MINIMUM TORQUE value to 10% above wrench maximum range
by pressing
UP
/DOWN
buttons. Once desired value has been set, press
ENTER
button
.
6. BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP
/DOWN
buttons to increase/decrease batch count. Mode Count increases each time target torque
is reached if a batch count of zero is entered. Mode Count is displayed as 01ofXX if a non-zero batch
count is entered and resets to 01 after batch count completed. Once desired value has been set, press
ENTER
button
.
7. PSET target screen is displayed labelled with next available PSET number from 01 to 10.
8. To enter additional torque pre-sets, repeatedly press
ENTER
button
until target torque screen is
displayed and repeat steps above.
Adding an Angle Pre-set
1. From target angle screen, press and hold
UNITS
U
button
for 3 seconds.
2. ADD PRE-SET confirmation screen is displayed. Highlight
YES
menu selection using
UP
/DOWN
buttons then press
ENTER
button
.
NO
menu selection returns to main menu without adding a PSET.
3. MINIMUM ANGLE screen is displayed. MINIMUM ANGLE is target value at which green progress lights,
audible alert and vibrator turn on. Initial MINIMUM ANGLE value is value from target angle screen.
MINIMUM ANGLE can be set from 0 to 360° by pressing
UP
/DOWN
buttons. Once desired target
angle value has been set, press
ENTER
button
.