Viewing Stored Torque and Angle Data
Torque data is stored in memory after each torque cycle if applied torque has reached target value. Torque
and angle data is stored in memory after each angle cycle if applied angle has reached target value. Memory
Indicator is displayed when data is stored in non-volatile memory.
1.
To view stored torque and angle data, from target torque or angle screen, press and hold
ENTER
button for 3 seconds.
2.
Highlight
SHOW DATA
menu selection by pressing
UP
/DOWN
buttons then press
ENTER
button
to display Show Data screen.
3.
In Show Data screen, scroll through each stored data record by pressing
UP
/DOWN
buttons.
Example: 02 = Show Data List Counter: TQ = Peak torque value
01 = Show Data List Counter: TQ = Peak torque value: ANG = Peak angle value
4.
Pressing
ENTER
button while on Show Data screen returns to main menu.
5.
NOTE:
A maximum of 50 data records can be stored in memory. Memory full icon will be
displayed when full. New data will replace oldest record until memory is cleared.
Deleting Stored Torque and Angle Data
1. From target torque or angle screen, press and hold
ENTER
button
for 3 seconds.
2. Highlight
CLEAR DATA
menu selection using
UP
/DOWN
buttons then press
ENTER
button
to
display CLEAR ALL DATA screen.
3. In CLEAR ALL DATA screen, highlight
YES
menu selection to delete all stored data, or
NO
menu
selection to exit without deleting data.
4. Press
ENTER
button after making selection.