6
NOTE:
If wrench is powered up in torque only measurement mode, angle is not zeroed until mode
is changed to angle measurement mode, at which time torque and angle zeroing begins
automatically after 2 seconds. Wrench should be placed on a stable surface with no torque
applied.
NOTE:
Pressing ENTER button while angle is zeroing will abort zeroing function to allow user
to select another measurement mode.
Torque Mode
1.
Set Target
Use
UP /DOWN
buttons to change TORQUE target value.
2.
Select Units of Measure.
Repeatedly press
UNITS
U
button while on target TORQUE screen
until desired units are displayed.
3.
Apply TORQUE
Grasp centre of handle, (DO NOT pull on battery end-cap) and slowly apply torque to fastener until
progress lights display green and a ½ second audible alert and handle vibration alerts user to stop.
4.
Release TORQUE
Note peak TORQUE reading flashing on LCD display for 10 seconds. Pressing
BACKLIGHT
button
while peak torque is flashing will continue to display value until button is released. Momentarily press
UP
/DOWN , ENTER
or
UNITS
U
button to immediately return to target TORQUE screen.
Reapplying TORQUE will immediately start another TORQUE measurement cycle.
5.
Recall Peak TORQUE Reading
To recall last peak TORQUE measurement, press and hold
BACKLIGHT
button for approximately
3 seconds. Peak TORQUE will flash for 10 seconds.
TORQUE ZEROING
ANGLE ZEROING
--
SET STILL
00
250.0
FT-LB
00
180°
ENTER
button
Target Angle Screen
Target Torque Screen
ENTER
button
ANGLE ZERO REQ