23
Enable/Disable Torque THEN Angle Mode
This function will allow user to enable or disable Torque THEN Mode.
1. From Mode Setup menu, use
UP
/DOWN
buttons to highlight
THEN DISABLED
selection (factory
default) then press
ENTER
button.
2. TQ THEN ANGLE enable/disable screen is displayed.
3. Use
UP
/DOWN
buttons to select ENABLE or DISABLE selection.
4. Press
ENTER
button to accept selection and exit to Mode Setup menu.
NOTE:
Menu selection indicates current configuration (ENABLED or DISABLED).
Torque THEN Angle Mode
Torque THEN Angle mode is setup by first setting a target torque and units then a target angle before
selecting Torque THEN Angle mode. In Torque THEN Angle mode, when applied torque reaches target
torque, wrench automatically switches to angle mode for angle measurement. Progress lights indicate
applied torque progress while torque is measured and angle when angle is measured.
1. From target torque screen, use
UP
/DOWN
buttons to set target torque and
UNITS
U
button to
select torque measurement units then press
ENTER
button.
2. Angle target screen is displayed. Use
UP
/DOWN
buttons to set target angle then press
ENTER
button.
3. Torque THEN Angle mode screen is displayed.
4. Apply torque until target is reached then rotate wrench to target angle.
NOTE:
UNITS
U
button can be used to select torque units while on Torque THEN Angle screen.
NOTE:
Torque THEN Angle Pre-sets are entered by pressing and holding
UNITS
U
button while
on Torque THEN Angle screen. Refer to "Adding a Torque Pre-set" and "Adding an Angle
Pre-set" in Basic section for parameter entry
.
NOTE:
Torque cycle is not recorded in memory unless both torque and angle reach targets.
NOTE:
Red and yellow progress lights turn on if torque exceeds 110% of wrench full-scale or if
angle exceeds target plus 4% in manual mode.
NOTE:
Red and yellow progress lights turn on if torque exceeds maximum torque or if angle
exceeds maximum angle in Pre-set mode.