17
Operational Information:
•
CAL: Date of last wrench calibration.
•
ISD: In-Service Date.
•
TCF: Torque Calibration Factor.
•
ACF: Angle Calibration Factor.
•
VER: Software version.
•
OVR CNT: Overtorque Counter tracks how many times an over-torque event occurred on wrench
(torque >125% of full-scale).
•
TQZ: Torque Zero Offset.
•
AZZ: Z-Axis Angle Zero Offset.
•
AZX: X-Axis Angle Zero Offset.
•
AZO+: Gyro Zero Offset at CW full-scale torque.
•
AZO-: Gyro Zero Offset at CCW full-scale torque
•
TFS+: CW Full-scale torque ADC value
•
TFS-: CCW Full-scale torque ADC value
•
Copyright
4. Pressing
ENTER
button exits Show Info screen and returns to Settings menu.
Setting Sleep Time
This function will allow user to set interval wrench enters power-down state following last applied torque or
button press.
1. From Settings menu, use
UP
/DOWN
buttons to highlight
SLEEP TIME
selection then press
ENTER
button.
2. SLEEP TIME screen is displayed.
3. Use
UP
/DOWN
buttons to select sleep interval.
Selectable Intervals:
•
2 MIN (factory default)
•
5 MIN
•
10 MIN
•
30 MIN
•
1 HR