Setting the rotation duration / incision rate
The rotation duration and the incision rate are selected with the same switch. The longer the setting of the
rotation duration, the shorter the incision rate. At step 0, i.e. the shortest rotation duration, the blades close
very quickly. At step 9, the longest rotation duration, the blades close very slowly.
The stripping head may not be externally braked whilst running. Otherwise there is no guarantee that
the blades will close to the set diameter, particularly with step 9.
Counterclockwise or clockwise rotation / no rotation
The desired rotation direction can be set with the changeover switch. This is especially important for the
twisting of stranded wires. The correct choice of rotation direction can also positively influence stripping
quality when stripping micro-coaxial cables.
ST215W only:
In the middle position the stripping head stops before the stripping, i.e. no twisting of the stranded wire
takes place. The cable must be pulled out while the blue LED is ON. A cleaning cycle follows.