Nitronic AG
Mattenstrasse 11
2555 Bruegg
Email: [email protected]
Switzerland
Phone: +41 32 373 70 70
17
30
19
6
Fit the stripping blades and calibrating the centering unit
Loosen the centering unit so that it is not tightened.
Set the diameter scale to 0.0mm (0.0 Inch).
Slowly push the big Allen screw
(6)
back and forth. This will cause the four stripping blades to
automatically fit into the tracks on the guide plate
Fig. 20
.
Now tighten the centering unit.
Fig. 20
Fig. 21
Tighten a bit the screw
(19)
(black)
By rotating the centering scale
(17),
fully open the centering jaws
(25)
and insert the calibrating pin
(30)
.
Then by rotating the centering scale
(17)
close the centering jaws as far as the calibrating pin
(30)
Fig.
21
.
Loosen screw
(19)
(black)
and turn the centering scale
(17)
clockwise to diameter
2.0 mm
. Retighten
carefully screw
(19) (black)
and remove calibrating pin
(30)
.
The ST215 is now ready for use.