FORM NO. 56043126 - CR 1100, CR 1200 -
35
SWEEPING SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Side broom lift actuator will not raise.
Note: Do all testing with key switch on, main broom lever raised (press the side broom raise button on the A2 display panel if side brooms are not
programmed to raise automatically).
Repair the wiring to motor.
Does the motor retract?
On the A1 board does the side broom lift
indicator red light stay on momentarily
while the motor is retracting?
Check for open circuit in lift motor wiring
to the A1 board. J1-35 GRA/VIO J1-23
GRN/ORN
Side broom(s) will not raise
Check for an open in lift motor.
At the A2 display panel is the side broom
decrease light on?
Substitute an A2 display panel.
Does the side broom(s) raise?
Replace lift motor
Replace the A1 control board
yes
yes
yes
no
no
no
no
no
yes