FORM NO. 56043126 - CR 1100, CR 1200 -
61
PROGRAMMABLE CONTROL OPTIONS
Back-up Alarm Mode Control:
FACTORY DEFAULT: 1 (reverse only)
RANGE: 0 - 4
The CR 1100/1200 may be equipped with an optional back-up alarm. This alarm can be programmed to operate at times other than backing up or it
may be turned off. To select the operating mode:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
horn switch
.
3
While holding the horn switch turn the
main power key switch
to the
on
position.
4
Continue to hold the horn switch until all indicators except the horn indicator turn off (approximately two seconds).
5
Release the horn switch.
6
The status display will now show a number from 0 to 4. Pressing and releasing the
horn switch
will increase the displayed value until 4 is
reached. The next press will return to 0. If 0 is selected, the back-up alarm will be disabled and will not sound at any time. If 1 is selected, the
alarm will sound only when backing up. If 2 is selected, the alarm will sound when driving forward or in reverse. It will be off in neutral. If 3 is
selected, The alarm will sound when backing up or if the hopper is being raised or lowered. If 4 is selected, The alarm will sound when driving
forward or in reverse or if the hopper is being raised or lowered.
7
To save the new setting, turn the
main power key switch
to the
off
position.
8
The new setting will be saved and will remain in effect until it is changed again.
Side Broom Mode Control:
FACTORY DEFAULT: 1 (always turns on with main broom)
RANGE: 0 - 2
The side brooms on the CR 1100/1200 are programmed to always come on when the main broom is
fi
rst activated. If this is not desired, the operating
mode of the side booms can be changed. To select the operating mode:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
side broom up/off and the scrub system off switches
.
3
While holding both switches turn the
main power key switch
to the
on
position.
4
Continue to hold both switches until all indicators except the side broom up/off and scrub off indicators turn off (approximately two seconds).
5
Release both switches.
6
The status display will now show a number from 0 to 2. Pressing and releasing the
side broom up/off switch
will increase the displayed value
until 2 is reached. The next press will return to 0. If 0 is selected, the side brooms will not come on with the main broom. They will be manual
control only. If 1 is selected, the side brooms will always come on when the main broom is initially turned on. If 2 is selected, the side brooms
will come on if they were used the last time the main broom was on otherwise they will not automatically come on.
7
To save the new setting, turn the
main power key switch
to the
off
position.
8
The new setting will be saved and will remain in effect until it is changed again.
Dust Control Mode Control:
FACTORY DEFAULT: 1 (always turns on with main broom)
RANGE: 0 - 2
The dust control on the CR 1100/1200 is programmed to always come on when the main broom is
fi
rst activated. If this is not desired, the operating
mode of the dust control can be changed. To select the operating mode:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
dust control and the scrub system off switches
.
3
While holding both switches turn the
main power key switch
to the
on
position.
4
Continue to hold both switches until all indicators except the dust control and scrub off indicators turn off (approximately two seconds).
5
Release both switches.
6
The status display will now show a number from 0 to 2. Pressing and releasing the
dust control switch
will increase the displayed value until 2
is reached. The next press will return to 0. If 0 is selected, the dust control will not come on with the main broom. It will be manual control only.
If 1 is selected, the dust control will always come on when the main broom is initially turned on. If 2 is selected, the dust control will come on if
it was used the last time the main broom was on otherwise it will not automatically come on.
7
To save the new setting, turn the
main power key switch
to the
off
position.
8
The new setting will be saved and will remain in effect until it is changed again.