- FORM NO. 56043126 - CR 1100, CR 1200
DUST CONTROL SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Dust control impeller motor will not run
Part B: Load Circuit
Note: Do all testing with the key switch on, hopper closed, dust control switch on, seat switch and foot pedal activated.
Dust control impeller motor
will not run
Inspect motor for possible
mechanical binding, (debris in
and around motor).
Reset or replace CB.
At the K6 solenoid load wire
BRN/WHT (+ battery input) check
for 36V to battery ground.
Repair or replace
defective wire.
Does the motor run?
Repair or replace the M5 dust
impeller motor
Replace K6 solenoid.
Does the motor run?
At the K6 solenoid load wire
ORN/GRN (+ output to motor)
check for 36V to battery ground.
Check for 36V at motor wires
ORN/GRN(+) & BLK(-)
Repair or replace
defective wires or
connectors at motor
Does the motor run?
Is the F4 15 amp CB open?
no
no
no
no
no
no
no
no
yes
yes
yes
yes