FORM NO. 56043126 - CR 1100, CR 1200 -
19
Display
Code
Error Description
Troubleshooting Actions
1
Side broom actuator overload
Check for binding or frozen side broom linkage &
actuator motor.
Check for short circuit in lift motor or wiring.
2
Output bank 1 overload (horn & shaker)
Run self-diagnostic for specific cause
3
Output bank 2 overload (contactors)
Run self-diagnostic for specific cause
4
Light circuit overload
Check for short circuit in bulb and wiring.
5
Scrub deck actuator overload
Run self-diagnostic for specific cause
6
Squeegee actuator overload
Run self-diagnostic for specific cause
7
Scrub motor overload
See scrub motor troubleshooting part B.
8
Main broom overload
See main broom motor troubleshooting part B.
9
Accessory contactor coil circuit short
Check for wiring problems at the K10 coil.
Check K10 coil resistance if below 116 ohms Replace.
10
Accessory contactor coil circuit current too high Same as Error 9 Replace coil. (Shorted Coil)
11
Accessory contactor coil circuit open
Check for open in coil & wiring.
Check for 36V at the K10 coil wire colors
YEL/BRN (+), BLU/ORN (-).
12
Horn circuit short
Check for wiring or horn shorted.
13
Horn circuit current too high
Same as Error 12 Replace Wiring or horn.
14
Horn circuit open
Check for open in wiring. Check for 36V at the Horn wire
colors VIO (+), VIO/BRN (-). Replace or repair.
15
Left scrub motor M2 contactor coil circuit short
Check for wiring problems at the K1 coil.
Check K1 coil resistance if below 116 ohms Replace.
16
Left scrub motor M2 contactor coil current too
high
Same as Error 15 Replace coil. (Shorted Coil)
17
Left scrub motor M2 contactor coil circuit open
Check for open in coil & wiring.
Check for 36V at the K1 coil wire colors
VIO (+), YEL/BLU (-).
18
Shaker circuit short
See shaker will not run troubleshooting flow chart.
19
Shaker circuit current too high
See shaker will not run troubleshooting flow chart.
20
Shaker circuit open
See shaker will not run troubleshooting flow chart.
21
Main broom contactor coil circuit short
Check for wiring problems at the K4 coil.
Check K4 coil resistance if below 194 ohms Replace.
22
Main broom contactor coil current too high
Same as Error 21 Replace coil. (Shorted Coil)
23
Main broom contactor coil circuit open
Check for open in coil & wiring.
Check for 36V at the K4 coil wire colors
VIO (+), GRN/GRA (-).
24
Center scrub motor M3 contactor coil circuit
short
Check for wiring problems at the K2 coil.
Check K2 coil resistance if below 116 ohms Replace.
25
Center scrub motor M3 contactor coil current too
high
Same as Error 24 Replace coil. (Shorted Coil)
26
Center scrub motor M3 contactor coil circuit
open
Check for open in coil & wiring.
Check for 36V at the K2 coil wire colors
VIO (+), WHT/VIO (-).
27
Door open solenoid coil circuit short
Check for wiring problems at the L4 coil.
Check L4 coil resistance if below 66 ohms Replace.
28
Door open solenoid coil current too high
Same as Error 27 Replace coil. (Shorted Coil)