FORM NO. 56043126 - CR 1100, CR 1200 -
21
Display
Code
Error Description
Troubleshooting Actions
51
Solution solenoid coil circuit short
Check for wiring problems at the L1 and L2 coils.
Check L1 and L2 coils resistance if below 70 ohms,
replace.
52
Solution solenoid coil current too high
Same as Error 51 Replace coil. (Shorted Coil)
53
Solution solenoid coil circuit open
Check for open in coil(s) & wiring.
Check for 36V at the L1 and L2 solution valve coil wire
colors VIO(+), YEL/GRN (-).
54
Hydraulic pump contactor coil circuit short
Check for wiring problems at the K11 coil.
Check K11 coil resistance if below 149 ohms Replace.
55
Hydraulic pump contactor coil current too high
Same as Error 54 Replace coil. (Shorted Coil)
56
Hydraulic pump contactor coil circuit open
Check for open in coil & wiring.
Check for 36V at the K11 coil wire colors
VIO (+), BLU/WHT (-).
57
Back-up alarm circuit short
Check alarm and wiring
58
Back-up alarm current too high
Check alarm and wiring
59
Back-up alarm circuit open
Check alarm and wiring
60
Side broom actuator circuit short
Check for short in wires or motor.
61
Side broom actuator circuit current too high
Check for binding of linkage.
62
Side broom actuator circuit open
See service manual section flowcharts.
63
Scrub deck actuator circuit short
Check for short in wires or motor.
64
Scrub deck actuator circuit current too high
Check for binding of linkage.
65
Scrub deck actuator circuit open
See service manual section flowcharts.
66
Squeegee actuator circuit short
Check for short in wires or motor.
67
Squeegee actuator circuit current too high
Check for binding of linkage.
68
Squeegee actuator circuit open
See service manual section flowcharts.
69
Содержание Cr 1100
Страница 72: ......