62
- FORM NO. 56043126 - CR 1100, CR 1200
PROGRAMMABLE CONTROL OPTIONS
Dust Control Mode Control with Hopper Up:
FACTORY DEFAULT: 2 (no change)
RANGE: 0 - 2
The dust control on the CR 1100/1200 can be programmed to turn on or off or stay in its current state when the hopper is raised for dumping. To
select the operating mode:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
dust control and the scrub pressure decrease switches
.
3
While holding both switches turn the
main power key switch
to the
on
position.
4
Continue to hold both switches until all indicators except the dust control and scrub pressure decrease indicators turn off (approximately two
seconds).
5
Release both switches.
6
The status display will now show a number from 0 to 2. Pressing and releasing the
dust control switch
will increase the displayed value until
2 is reached. The next press will return to 0. If 0 is selected, the dust control will turn off when the hopper is raised. If 1 is selected, the dust
control will turn on when the hopper is raised. If 2 is selected, the dust control will remain in the same state that it was in prior to raising the
hopper (no change).
7
To save the new setting, turn the
main power key switch
to the
off
position.
8
The new setting will be saved and will remain in effect until it is changed again.
Shaker Mode Control:
FACTORY DEFAULT: 1 (timed – manual control)
RANGE: 0 - 3
The dust control
fi
lter shaker on the CR 1100/1200 is programmed to run for an adjustable period of time when the operator depresses the shaker
switch on the control panel. The shaker can be programmed to operate in a momentary fashion or automatically. To select the operating mode:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
shaker and scrub system off switches
.
3
While holding both switches turn the
main power key switch
to the
on
position.
4
Continue to hold both switches until all indicators except the shaker and scrub off indicators turn off (approximately two seconds).
5
Release both switches.
6
The status display will now show a number from 0 to 3. Pressing and releasing the
shaker switch
will increase the displayed value until 3 is
reached. The next press will return to 0. If 0 is selected, the shaker will turn on only when the control panel switch is held (momentary). If 1 is
selected, the shaker will run for an adjustable period of time (see above to adjust time period). If 2 is selected, the shaker will automatically run
for an adjustable period of time when the main broom is turned off. If 3 is selected, the shaker will automatically run for an adjustable period of
time when the hopper is lowered all the way down after being in the up position.
7
To save the new setting, turn the
main power key switch
to the
off
position.
8
The new setting will be saved and will remain in effect until it is changed again.
Control Assembly Revision Display:
To display the revision of the control assembly, perform the following steps:
1
Turn
the
main power key switch
to the
off
position.
2
Press and hold the
hopper up switch
.
3
While holding the hopper up switch turn the
main power key switch
to the
on
position.
4
Continue to hold the hopper up switch until all indicators except the hopper up indicator turn off (approximately two seconds).
5
Release the hopper up switch.
6
The status display will now show a letter representing the revision of the display assembly.
7
To exit this mode, turn the
main power key switch
to the
off
position.
Содержание Cr 1100
Страница 72: ......