FORM NO. 56043126 - CR 1100, CR 1200 -
31
SWEEPING SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Main Broom will not turn.
Part B: Electrical Load Circuit
Note 1: Do all testing with the key switch on, broom lever lowered, hopper open indicator light off and drive pedal activated (Place in forward or
reverse).
Main broom will not turn
Inspect main broom for
possible mechanical binding,
damage broom lug inserts
and debris wrapped around
motor or broom.
At the K4 solenoid load wire
RED 6-1 (battery input +) check
for 36V to battery ground.
Remove debris and make
any repairs or replace
damage parts. Does the
broom run?
Repair or replace defective
wire(s). Does the broom run?
Repair or replace the M1
main broom motor
Replace K4 solenoid.
Does the broom run?
At the K4 solenoid load wire RED
6-2 (output to broom motor +)
check for 36V to battery ground.
Check for 36V at main broom
motor.
Repair or replace defective
wire(s) + or -.
Does the broom run?
yes
yes
yes
yes
no
no
no
no
no
no
no