CASE 7
BISOMAC308 is too hot
Problem
Solution
1 Voltage of input power is too high
The supply voltage should not 10 %,
see Section 2.1.
2 Air supply to Motor is in bad condition.
Improve air ventilation on fan cover of
BISOMAC308
3 Frequency use of BISOMAC308.
Strict observance of BISOMAC308 operation hours,
see Section 6.
CASE 8
Press “Down” Button, but
BISOMAC308 will not descend.
Problem
Solution
1
Connector of Overspeed Detection
Device is unplugged.
Connect Connector of Overspeed Detection Device
properly.
2
Overspeed Detection Device may be
activated.
Reset Overspeed Detection Device.
HOW TO RESET
A) Lift the hoist by about 4 inch (10 cm).
B) Lower the Reset Lever of Overspeed Detection
Device.
NOTE:
DO NOT reset forcefully. When the pin inside the
lever of Overspeed Detection Device is damaged,
you may not be able to reset Overspeed Detection
Device.