7.3 Test procedures for Lifting and use of the Emergency Stop
A) Check that none of the bolts/nuts and Operator’s Manual Cap are loose.
B) Check the visual appearance of the Traction Hoist (Include Cables and
Connectors) that there is no damaged place such as crack or deformation.
C) Check that the emergency stop button cover and ascent/descent button cover
are not damaged such as crack.
D) Make sure the BISOMAC308 is connected to the stirrup properly and the AC
Power Plug is connected to power source properly. And check circuit breaker.
E) Raise the platform about 40 in. (100 cm) off the ground and then lower it to
its original position. Repeat this procedure several times. Check that there
is not abnormal vibration such as the Traction Hoist is shaking.
F) Check that hour meter is working normally.
G) Press the Emergency Stop Button to disconnect the power to the
BISOMAC308.
H) Make sure that the Indication light (RED) for the Emergency Stop Button is lit.
I)
Press the Operation Button to confirm that the BISOMAC308 will not operate.
J) Reset the Emergency Stop Button and confirm that the BISOMAC308 will
operate.
Testing procedure when REMOTE CONTROL PENDANT SWITCH is connected
A) Check that none of the bolts/nuts and Operator’s Manual Cap are loose.
B) Check the visual appearance of the Traction Hoist (Include Cables and
Connectors) that there is no damaged place such as crack or deformation.
C) Check that the emergency stop button cover and ascent/descent button cover
are not damaged such as crack.
D) Make sure the BISOMAC308 is connected to the stirrup properly and the AC
Power Plug is connected to power source properly. And check circuit breaker.
E) Press the Operation Button of the PENDANT SWITCH to raise the platform
about 40 in. (100 cm) off the ground and then lower it to its original position.
Repeat this procedure several times. Check that there is not abnormal
vibration such as the Traction Hoist is shaking.
F) Check that hour meter is working normally.
G) Press the Emergency Stop Button of the PENDANT SWITCH and shutdown
the power supply of BISOMAC308.
H) Verify that the red color display lamp of the Emergency Stop Button of the
main body lights up.
I)
Press the Operation Button of the PENDANT SWITCH and verify that
BISOMAC308 doesn’t operate.
J) Press the Operation Button of the main body and verify that BISOMAC308
doesn’t operate.
K) Reset the Emergency Stop Button of the PENDANT SWITCH, and verify that
the platform moves up and down once again.
L) Press the Emergency Stop Button of the main body and shutdown the power
supply of BISOMAC308.
M) Verify that the red color display lamp of the Emergency Stop Button of the
main body lights up.
Содержание BISOMAC308
Страница 1: ...NIHON BISOH CO LTD BISOMAC308 Electric Traction Hoist Operator s Manual ...
Страница 15: ...Nihon Bisoh Co Ltd BISOMAC308 1Phase 3Phase MM2015 9 KH 2015001 12 R Q U OP2 O S N M P T SA ...
Страница 16: ...13 Nihon Bisoh Co Ltd BISOMAC308 1Phase 3Phase MM2015 9 KH 2015001 V X I Y Z W OP1 ...
Страница 56: ...Nihon Bisoh Co Ltd BISOMAC308 1Phase 3Phase MM2015 9 KH 2015001 NOTE ...
Страница 58: ......