Height Rider/SP Series
Operating & Safety Instructions
English/USA – 01/18
Original instructions
25
EMERGENCY PROCEDURES
1)
Push in
red emergency stop to shut down
all
machine movement.
2)
Release
both emergency stops to restore normal controls.
In the event that the controls fail, the cage overload is activated due to contact with a fixed object or a
cage operator is incapacitated, the booms can be operated from the base location as described below:
If normal controls are available (fastest recovery time):
1)
Turn key switch to ground, press the green button and operate the desired function lever(s).
If normal controls are
not
available:
2)
Locate the
manual hand pump
under the control side canopy.
3)
Attach supplied handle to the hand pump.
4)
Move and hold the desired boom function lever in the required direction.
5)
Pump the hand pump to activate the selected function.
6)
Release the lever and stop pumping to halt machine movement.
7)
If recovering the machine because cage overload has deactivated the machine due to contact
with a fixed object, then moving the machine slightly using steps 1-5 should be sufficient to re-
enable normal operation. The cage overload alarm and visual warning will cease once normal
controls are available.
8)
If normal controls are still not available, continue pumping to lower the machine manually.