2.1.35
If the platform or elevating assembly becomes caught, snagged or otherwise prevented from normal
motion by adjacent structure or other obstacles, such that control reversal does not free the platform,
all personnel shall be removed from the platform safely before attempts are made to free the platform
using ground controls.
2.1.36
When the machine is not in use always stow the booms correctly.
NEVER LEAVE
THE KEY IN THE MACHINE
, if it is to be left for any period of time. Use wheel
chocks if leaving on an incline.
2.1.37
The engine must be shut down while fuel tanks are being filled. Fuelling must be done in a well-
ventilated area free of flame, sparks or any other hazard that may cause fire or explosion.
PETROL
(GASOLINE) AND DIESEL FUELS ARE FLAMMABLE.
2.1.38
NEVER START THE NIFTYLIFT IF YOU SMELL PETROL (GASOLINE), LIQUID
PROPANE OR DIESEL FUEL. THESE FUELS ARE HIGHLY FLAMMABLE
2.1.39
The operator must ensure that engine powered machines are used in a well-ventilated area to minimise
the risk of carbon monoxide poisoning.
2.1.40
The operator shall implement means provided to protect against use by unauthorised persons.
2.1.41
Never remove anything that may affect the stability of the machine such as, but not limited to, batteries,
covers, engines, tyres or ballast.
2.1.42
The operator must ensure that the controls are not obstructed (e.g. by tools or equipment) and
clear
access to the Emergency Stop
is available at all times.
2.1.43
All persons in the cage must take suitable precautions to prevent items falling or being ejected from the
cage. E.g. Tethering tools to the machine or operator if practical and an assessment of any resulting
risks is acceptable.
2.1.44
Hydraulic oil escaping under pressure can penetrate the skin and cause
serious injury
. Do not allow hydraulic oil to squirt or spray.
Seek
immediate medical attention in the event of hydraulic oil
penetrating the skin.
Wear chemical-resistant protective gloves and
suitable eye protection when handling hydraulic oil. Relieve system
pressure before removing any hydraulic connections, undo fittings
slowly to make sure there is no residual pressure. If pressure is
detected, allow it to be released slowly before completely removing
hose. Fluid leaks may not be visible to the naked eye. Use a piece of cardboard to check for leaks, not
your hand.
Never
install hydraulic lines or components that are damaged.
2.1.45
The HR12 MK2 has been tested in a UKAS accredited electromagnetic compatibility (EMC) chamber
and complies with the relevant clauses of EN61326-3-1:2008, EN61000-6-2:2005 for emissions and
immunity. Niftylift offer a generator option on this machine, but cannot control the device that is
connected to the system or the resulting variation in the amplitude of electrical noise produced when
operating the generator. Niftylift therefore recommend that the generator is not used when the machine
is located near any equipment that may be sensitive to electromagnetic disturbance.