background image

7.1) “CHARGE” CARD also battery powered

The unit is equipped with a power transformer that can provide the motor’s power requirement and that of the electronic card so
it can all be powered directly by the mains. 

If you want the system to continue working  in the case of a power cut then you have to add a suitable battery and the relative
battery charger card.

Due  to  the  size  of  the  battery  it  must  be  installed  externally  to  the  motor  unit  and  connected  to  two  terminals  on  the  battery
charger card; the latter must be connected to the connector on the unit.

8) MAINTENANCE:

The  card,  being  electronic,  needs  no  particular  maintenance.  However  check  periodically,  at  least  twice  a  year,  the  perfect
efficiency and adjustment of the device that controls maximum motor force and, if required, adjust with the trimmer. 
Check effectiveness of the safety devices (photoelectric cells, pneumatic edges, etc.) and correct functioning of the flashing light.

TECHNICAL FEATURES OF THE UNIT:

Mains power

: 230 Vac ±10%  ,  50 - 60  Hz

Battery power

: 21 ÷ 28 Vdc (> 6Ah capacity)

Max. Access: current 24 Vdc

: 200 mA

Max. flashing light power

: 25 W ( 24 Vdc)

Max gate-open power indicator

: 2 W ( 24 Vdc)

Pause time

: from  1 to 1023 seconds

Encoder resolution

: 4.73 degrees (76 pulses/rev)

Working temperature

: -20 ÷ 70 °C

Eng li sh

3 0

Содержание ROBO CLIMBER

Страница 1: ...lektronische Steuerkarte f r Kolbentorantri ebe ROBO PLUS oder CLIMBER Installationsanleitu ngen Ficha electr nica de control para accionadores ROBO PLUS o CLIMBER Manual de instrucciones para la inst...

Страница 2: ...and service the equipment It is the responsibility of the installer to ensure that the equipment is correctly and professionally installed in compliance with all relevant regulations and standards ap...

Страница 3: ...s both OFF Switches 1 2 Off Off Hold to run control functioning mode On Off Semiautomatic functioning mode Off On Automatic functioning mode Automatic Closing On On Automatic Close Always functioning...

Страница 4: ...semiautomatic and automatic There are also some sophisticated functions like Reclose immediately after Photocell and Always reclose Flashing light also in pause operating functions like Slow Start an...

Страница 5: ...open and close manoeuvres PHOTOCELL should trigger mainly in closing while PHOTOCELL2 mainly in opening When the gearmotors are made they are set for clockwise rotation of the shaft in opening and ant...

Страница 6: ...tioning OPEN STOP CLOSE STOP 13 Open Timer Input for opening which could be timer controlled 14 Partial Opening Input for partial opening pedestrian opening 41 42 2nd radio channel Output for the seco...

Страница 7: ...variation does not have any immediate effect Quick flashing at 5 second intervals means that the release lever is open the power voltage is insufficient or an incorrect programme has been selected se...

Страница 8: ...possible to programme these distances manually one by one so you can make the gate door stop in exactly the places you want To simplify the programming there is a completely automatic programming pha...

Страница 9: ...earch 4 1 PROGRAMMING As an alternative to the initial limits search which only takes place if the gearmotor has never been installed before it is possible at any time to activate an automatic limit s...

Страница 10: ...key on the card to move the gate door in the closing phase until the mechanical stop is reached 3 If you want besides the CLOSE key you can also press the key to accelerate movement 4 When the gate do...

Страница 11: ...er than B 1 Set the dip switches as indicated in this way the manual search for distance A is selected 2 Press the OPEN or CLOSE keys to open or close the gate door until it reaches the point wanted 3...

Страница 12: ...say 25 seconds turn dip switches 5 4 and 1 ON the sum of 16 8 1 25 3 Once you have selected the time you can proceed to memorisation Pause Time for automatic manoeuvres is memorised with this procedu...

Страница 13: ...econds of preflashing Switch 3 On Condominium function In the Condominium functioning mode once an opening manoeuvre has started for instance with a Step by Step pulse this movement cannot be interrup...

Страница 14: ...he effect the adjustment has on the trimmer it is best to wait for movement to start and for the gate door to reach standard speed Also ensure for safety reasons that if the clutch intervenes three ti...

Страница 15: ...he connector on the unit 8 MAINTENANCE The card being electronic needs no particular maintenance However check periodically at least twice a year the perfect efficiency and adjustment of the device th...

Отзывы: