background image

4.3) MANUALLY PROGRAMMING THE DISTANCES:

All the distances described in the previous chapter can be programmed manually:

4.3.1) Automatic limits search (all gate/door limits):

An “automatic limits search” is carried out which is identical to the “initial limits search” except that the former can be activated
at any time even if the gearmotor is already installed and the memory has correct distance values stored

1)

Set the dip-switches as indicated; in this way the “automatic limits search” is selected.
If dip-switch 10 is OFF point “C” is positioned 5 cm from point “0”, if it is ON point “C” corresponds to “0”.

2)

Briefly press the “CLOSE” key on the control card.

3)

Wait until the search procedure has terminated (slow closing, slow opening and, lastly, fast reclosing) 

4)

Now  that  the  “automatic  limits  search”  is  terminated,  turn  the  programming  switches  “OFF”,  set  the  function  dip-

switches on the mode required and the gearmotor is ready to use.

All the distances measured with the above procedure are memorised automatically. 
Subsequent to an automatic search, if you wish to, you can modify any of the distances measured (except for distance 0) by
means of the manual search.

4.3.2) Manual search for distance “0”

(Mechanical Stop in CLOSING):

The “manual search for distance 0” is carried out with this procedure, that is, you programme the maximum closing point. 

1)

Set the dip-switches as indicated; in this way the “manual search for distance 0” is selected.

2)

Press the “CLOSE” key on the card to move the gate/door in the closing phase until the mechanical stop is reached

3)

If you want, besides the “CLOSE” key, you can also press the “<<>>” key to accelerate movement.

4)

When the gate/door has reached the mechanical stop, the distance has been measured so you can then proceed to

memorisation.

With this procedure the maximum closing point has been found and memorised; this measurement is fundamental because all
other measurements start from this point.

4.3.3) Manual search for distance “C”

(Stopping point wanted in CLOSING):

The “manual search for distance C” is carried out with this procedure, that is, you programme the closing point you want; this is
the point at which the gate/door stops in the closing manoeuvre. When using like RO1024, this distance is normally set a few
centimetres from the mechanical stop in closing while in the case of using as CR2024, it is normally set a few millimetres from
the mechanical stop device. Obviously this distance must always be more than distance “0”.

1)

Set the dip-switches as indicated; in this way the “manual search for distance C” is selected.

2)

Press the keys “OPEN” or “CLOSE” to open or close the gate/door until it reaches the point wanted.

3)

Movement can also be accelerated by pressing the “<<>>” key.

4) 

When  the  gate/door  has  reached  the  point  wanted  the  distance  has  been  measured  so  you  can  then    proceed  to

memorisation.

With this procedure the closing point required has been measured and memorised.

Eng li sh

2 5

1 2 3 4 5 6 7 8 9 10

1 2

1 2 3 4 5 6 7 8 9 10

1 2

USE AS FOR AN “RO1024” SLIDING GATE

USE AS FOR A “CR2040” SECTIONAL OR SLIDING DOOR

1 2 3 4 5 6 7 8 9 10

1 2

1 2 3 4 5 6 7 8 9 10

1 2

Содержание ROBO CLIMBER

Страница 1: ...lektronische Steuerkarte f r Kolbentorantri ebe ROBO PLUS oder CLIMBER Installationsanleitu ngen Ficha electr nica de control para accionadores ROBO PLUS o CLIMBER Manual de instrucciones para la inst...

Страница 2: ...and service the equipment It is the responsibility of the installer to ensure that the equipment is correctly and professionally installed in compliance with all relevant regulations and standards ap...

Страница 3: ...s both OFF Switches 1 2 Off Off Hold to run control functioning mode On Off Semiautomatic functioning mode Off On Automatic functioning mode Automatic Closing On On Automatic Close Always functioning...

Страница 4: ...semiautomatic and automatic There are also some sophisticated functions like Reclose immediately after Photocell and Always reclose Flashing light also in pause operating functions like Slow Start an...

Страница 5: ...open and close manoeuvres PHOTOCELL should trigger mainly in closing while PHOTOCELL2 mainly in opening When the gearmotors are made they are set for clockwise rotation of the shaft in opening and ant...

Страница 6: ...tioning OPEN STOP CLOSE STOP 13 Open Timer Input for opening which could be timer controlled 14 Partial Opening Input for partial opening pedestrian opening 41 42 2nd radio channel Output for the seco...

Страница 7: ...variation does not have any immediate effect Quick flashing at 5 second intervals means that the release lever is open the power voltage is insufficient or an incorrect programme has been selected se...

Страница 8: ...possible to programme these distances manually one by one so you can make the gate door stop in exactly the places you want To simplify the programming there is a completely automatic programming pha...

Страница 9: ...earch 4 1 PROGRAMMING As an alternative to the initial limits search which only takes place if the gearmotor has never been installed before it is possible at any time to activate an automatic limit s...

Страница 10: ...key on the card to move the gate door in the closing phase until the mechanical stop is reached 3 If you want besides the CLOSE key you can also press the key to accelerate movement 4 When the gate do...

Страница 11: ...er than B 1 Set the dip switches as indicated in this way the manual search for distance A is selected 2 Press the OPEN or CLOSE keys to open or close the gate door until it reaches the point wanted 3...

Страница 12: ...say 25 seconds turn dip switches 5 4 and 1 ON the sum of 16 8 1 25 3 Once you have selected the time you can proceed to memorisation Pause Time for automatic manoeuvres is memorised with this procedu...

Страница 13: ...econds of preflashing Switch 3 On Condominium function In the Condominium functioning mode once an opening manoeuvre has started for instance with a Step by Step pulse this movement cannot be interrup...

Страница 14: ...he effect the adjustment has on the trimmer it is best to wait for movement to start and for the gate door to reach standard speed Also ensure for safety reasons that if the clutch intervenes three ti...

Страница 15: ...he connector on the unit 8 MAINTENANCE The card being electronic needs no particular maintenance However check periodically at least twice a year the perfect efficiency and adjustment of the device th...