QUICK GUIDE:

Do not install the motor without the “Mechanical travel stop devices”!

Install the gearmotor , the control devices ( key switch or push button) and safety devices (emergency stop, photocells,  sensitive
edges and flashing light) and then  connect the unit as follows: 

Turn the unit on and check that the input  voltage on terminals 1and 2 is 230Vac, and the output voltage on terminals 5 and 6 is
24Vdc; the LEDs on ‘active’ inputs  should be on and the OK LED should blink at 1 second intervals. The OK ENCODER LEDs
signal each movement of the gate/door.

Check movement direction by pressing the CLOSE key twice: if the gate/door opens turn the unit off, turn the MOTOR connector
180° and turn the jumper J8 in the opposite position.

To set up a new installation, or if the control card memory has been cancelled carry out procedures 1 and 2 below:

1) Press the CLOSE key on the card for a moment.

2) Set the FUNCTIONS and PROGRAMMING dip-switches as indicated and then press the CLOSE key on the card.

If dip switch 10 is OFF, point “C” is positioned 5 cm from point “0”; if it is ON, point “C” corresponds to “0”.

Wait for the search procedure to finish (slow closing, slow opening ending with quick reclosing) 

Set the FUNCTION dip-switches as required with the PROGRAMMING switches both “OFF”.

Switches 1-2: Off Off 

= “ Hold to run control “ functioning mode

On  Off

= “Semiautomatic” functioning mode

Off  On

= “Automatic” functioning mode (Automatic Closing)

On  On

= “Aut Close Always” functioning mode

Switch 3

On

= Condominium functioning mode

Switch 4   

On

= Cancel STOP in the step-by-step cycle 

Switch 5   

On

= Preflashing

Switch 6   

On

= Flashing also in Pause

Switch 7   

On

= Recloses immediately after Photocell (only if in the Automatic functioning mode)

Switch 8   

On

= Safety device (Photocell) also in opening

Switch 9   

On

= Safety devices (Photocell and Photocell 2) also at the beginning of each movement

Switch 10 

On

= Automatic realignment, if required, when power returns

If the automatic mode is selected (Switch 2 “On”) Pause Time is preset at 30 seconds. To alter it see Chapter 4.4.

Adjust the CLUTCH trimmer until the required triggering threshold is reached (thrust is increased by turning it clockwise).

Eng li sh

1 8

- (0 v)

MOTOR

8 A

315mAT

FUSE

FUSE

 

1

MOT

OR

FUSE
3,15 A

2

 

3

4

+
-

“OK” LED 
 

FUNCTIONS

3

1 2

J8

PROGRAMMING

CLOSE KEY

 

9
8

6
5

+ (24v)

 

7

11

10

13
12

14

 

41

43
42

44

CLUTCH

OK ENCODER

AERIAL 

2ND CH. 

RADIO 

PARTIAL OPENING 

TIMER OPENING 
SbS 
PHOTOCELL 2 
PHOTOCELL 
STOP 
GATE OPEN INDICATOR 

COMMON 
+(24v)    24  Vdc  
MAX 200 mA 

LUCY 24 Vdc 

MAX 25 W  

230 Vac 

50-60 Hz  

PARTIAL OPENING 

TIMER OPENING 

SbS 

PHOTOCELL 2 

PHOTOCELL 

STOP

1 2 3 4 5 6 7 8 9 10

1 2

1 2 3 4 5 6 7 8 9 10

1 2

Switch 10 “OFF”
recommended for sliding
gates “RO1024” 

Switch 10 “ON”
recommended for
sectional or sliding doors
”CR2040”

Содержание ROBO CLIMBER

Страница 1: ...lektronische Steuerkarte f r Kolbentorantri ebe ROBO PLUS oder CLIMBER Installationsanleitu ngen Ficha electr nica de control para accionadores ROBO PLUS o CLIMBER Manual de instrucciones para la inst...

Страница 2: ...and service the equipment It is the responsibility of the installer to ensure that the equipment is correctly and professionally installed in compliance with all relevant regulations and standards ap...

Страница 3: ...s both OFF Switches 1 2 Off Off Hold to run control functioning mode On Off Semiautomatic functioning mode Off On Automatic functioning mode Automatic Closing On On Automatic Close Always functioning...

Страница 4: ...semiautomatic and automatic There are also some sophisticated functions like Reclose immediately after Photocell and Always reclose Flashing light also in pause operating functions like Slow Start an...

Страница 5: ...open and close manoeuvres PHOTOCELL should trigger mainly in closing while PHOTOCELL2 mainly in opening When the gearmotors are made they are set for clockwise rotation of the shaft in opening and ant...

Страница 6: ...tioning OPEN STOP CLOSE STOP 13 Open Timer Input for opening which could be timer controlled 14 Partial Opening Input for partial opening pedestrian opening 41 42 2nd radio channel Output for the seco...

Страница 7: ...variation does not have any immediate effect Quick flashing at 5 second intervals means that the release lever is open the power voltage is insufficient or an incorrect programme has been selected se...

Страница 8: ...possible to programme these distances manually one by one so you can make the gate door stop in exactly the places you want To simplify the programming there is a completely automatic programming pha...

Страница 9: ...earch 4 1 PROGRAMMING As an alternative to the initial limits search which only takes place if the gearmotor has never been installed before it is possible at any time to activate an automatic limit s...

Страница 10: ...key on the card to move the gate door in the closing phase until the mechanical stop is reached 3 If you want besides the CLOSE key you can also press the key to accelerate movement 4 When the gate do...

Страница 11: ...er than B 1 Set the dip switches as indicated in this way the manual search for distance A is selected 2 Press the OPEN or CLOSE keys to open or close the gate door until it reaches the point wanted 3...

Страница 12: ...say 25 seconds turn dip switches 5 4 and 1 ON the sum of 16 8 1 25 3 Once you have selected the time you can proceed to memorisation Pause Time for automatic manoeuvres is memorised with this procedu...

Страница 13: ...econds of preflashing Switch 3 On Condominium function In the Condominium functioning mode once an opening manoeuvre has started for instance with a Step by Step pulse this movement cannot be interrup...

Страница 14: ...he effect the adjustment has on the trimmer it is best to wait for movement to start and for the gate door to reach standard speed Also ensure for safety reasons that if the clutch intervenes three ti...

Страница 15: ...he connector on the unit 8 MAINTENANCE The card being electronic needs no particular maintenance However check periodically at least twice a year the perfect efficiency and adjustment of the device th...

Отзывы: