2.2) WIRING DIAGRAM:
Fig. 2
NOTE:
Only qualified personnel must carry out the installation and subsequent maintenance expertly and in total conformity with the
machine directive 89/392 and with EN 60204 regarding electrical wiring of machines. Whoever carries out these jobs is held
responsible for any damage caused
2.3) DESCRIPTION OF THE CONNECTIONS:
Connections
1-2
: 230 V a.c.
= 230 V a.c. 50/60 Hz
3-4
: Flashing light
= Output for connection to the 24 V d.c. flashing light, maximum lamp power: 25 W
5-6
: 24 V d.c.
= 24 V d.c. output for supplying accessories (Photocell, Radio, etc.) maximum 200 mA
7
: Common
= Common for all inputs (terminal 6 can also be used as the Common)
8
: Gate open Indicator = 24 V d.c. output for gate/door open indicator light, maximum indicator power 2 W
9
: Stop
= Input with STOP function (Emergency, shutdown or extreme safety)
10
: Photocell
= Input for safety devices (Photocells, pneumatic edges)
11
: Photocell2
= Input for safety devices with triggering in opening (Photocells, pneumatic edges)
12
: Step-by-Step
= Input for cyclic functioning (OPEN STOP CLOSE STOP)
13
: Open-Timer
= Input for opening (which could be timer controlled)
14
: Partial Opening
= Input for partial opening (pedestrian opening)
41-42
: 2nd radio channel = Output for the second radio receiver channel if existing
43-44
: Aerial
= Input for the radio receiver aerial
The following connections are done in the factory:
PRIMARY TRANS.
= Primary winding of the power transformer
SECOND. TRANS.
= Secondary winding of the power transformer
MOTOR
= Output for 24 V d.c. motor connection
RELEASE
= Microswitch that detects the motor released state (hand manoeuvre)
ENCODER
= Connections to the optical reader that detects shaft rotation
There are an additional two slots for optional cards:
RADIO
= Slot for
Nice
radio receivers
CHARGE
= Slot for battery charger card
Eng li sh
2 1
MICROPROCESSOR
ALT
9
CHARGE CARD
" RADIO " CARD
8 A
FUSE
ENCODER
FUSE
315mAT
MOT
OR
FUSE
3,15 A
1
2
COMMON RELA
Y
OP-CL
RELA
Y
3
8
4
UNLOCK
6
5
+ (24v)
7
- (0 v)
+
-
OK ENCODER
CLUTCH
OK
3
1 2
-J8-
CL
<<>>
OP
FUNCTIONS
PROGR.
11
FOTO
10
41
43
42
13
12
14
44
AP. P.
APRE
P. P.
FOTO2
AERIAL
2ND CH.
RADIO
PARTIAL OPENING
TIMER OPENING
SbS
PHOTOCELL 2
PHOTOCELL
STOP
GATE OPEN INDICATOR
COMMON
24 Vcc
MAX 200 mA
LUCY 24 Vdc
MAX 25 W
230 Vac
50-60Hz
SEC.
TRANSFORMER
PRIM.
TRANSFORMER