2.2) WIRING DIAGRAM:

Fig. 2

NOTE:

Only qualified personnel must carry out the installation and subsequent maintenance expertly and in total conformity with the
machine  directive  89/392  and  with  EN  60204  regarding  electrical  wiring  of  machines.  Whoever  carries  out  these  jobs  is  held
responsible for any damage caused

2.3) DESCRIPTION OF THE CONNECTIONS:

Connections

1-2

: 230 V a.c.

= 230 V a.c. 50/60 Hz

3-4

: Flashing light

= Output for connection to the 24 V d.c. flashing light, maximum lamp power: 25 W

5-6

: 24 V d.c.

= 24 V d.c. output for supplying accessories (Photocell, Radio, etc.) maximum 200 mA

7

: Common

= Common for all inputs (terminal 6 can also be used as the Common)

8

: Gate open Indicator = 24 V d.c. output for gate/door open indicator light, maximum indicator power 2 W

: Stop

= Input with STOP function (Emergency, shutdown or extreme safety)

10

: Photocell

= Input for safety devices (Photocells, pneumatic edges)

11

: Photocell2

= Input for safety devices with triggering in opening (Photocells, pneumatic edges)

12

: Step-by-Step

= Input for cyclic functioning (OPEN STOP CLOSE STOP)

13

: Open-Timer

= Input for opening (which could be timer controlled)

14

: Partial Opening

= Input for partial opening (pedestrian opening)

41-42

: 2nd radio channel = Output for the second radio receiver channel if existing

43-44

: Aerial

= Input for the radio receiver aerial

The following connections are done in the factory:

PRIMARY TRANS.

= Primary winding of the power transformer

SECOND. TRANS.

= Secondary winding of the power transformer

MOTOR

= Output for 24 V d.c. motor connection

RELEASE

= Microswitch that detects the motor released state (hand manoeuvre)

ENCODER

= Connections to the optical reader that detects shaft rotation

There are an additional two slots for optional cards:

RADIO 

= Slot for 

Nice

radio receivers

CHARGE

= Slot for battery charger card

Eng li sh

2 1

MICROPROCESSOR

ALT

9

CHARGE CARD

 " RADIO " CARD

8 A

FUSE

ENCODER

FUSE

315mAT

MOT

OR

FUSE

3,15 A

1

2

COMMON RELA

 

 

OP-CL

 RELA

Y

3

8

4

UNLOCK 

 

6
5

+ (24v)

 

7

- (0 v)

+
-

OK ENCODER

CLUTCH

OK

3

1 2

-J8-

CL

<<>>

OP

FUNCTIONS

PROGR.

11

FOTO

10

 

41

43
42

 

13
12

14

44

AP. P.

APRE

P. P.

FOTO2

AERIAL 

2ND CH. 

RADIO 

PARTIAL OPENING 
TIMER OPENING 
SbS 
PHOTOCELL 2 
PHOTOCELL 
STOP 
GATE OPEN INDICATOR 
COMMON 
24  Vcc  

MAX 200 mA 

LUCY 24 Vdc 

MAX 25 W 

230 Vac 

50-60Hz 

SEC. 

TRANSFORMER

PRIM. 

TRANSFORMER

Содержание ROBO CLIMBER

Страница 1: ...lektronische Steuerkarte f r Kolbentorantri ebe ROBO PLUS oder CLIMBER Installationsanleitu ngen Ficha electr nica de control para accionadores ROBO PLUS o CLIMBER Manual de instrucciones para la inst...

Страница 2: ...and service the equipment It is the responsibility of the installer to ensure that the equipment is correctly and professionally installed in compliance with all relevant regulations and standards ap...

Страница 3: ...s both OFF Switches 1 2 Off Off Hold to run control functioning mode On Off Semiautomatic functioning mode Off On Automatic functioning mode Automatic Closing On On Automatic Close Always functioning...

Страница 4: ...semiautomatic and automatic There are also some sophisticated functions like Reclose immediately after Photocell and Always reclose Flashing light also in pause operating functions like Slow Start an...

Страница 5: ...open and close manoeuvres PHOTOCELL should trigger mainly in closing while PHOTOCELL2 mainly in opening When the gearmotors are made they are set for clockwise rotation of the shaft in opening and ant...

Страница 6: ...tioning OPEN STOP CLOSE STOP 13 Open Timer Input for opening which could be timer controlled 14 Partial Opening Input for partial opening pedestrian opening 41 42 2nd radio channel Output for the seco...

Страница 7: ...variation does not have any immediate effect Quick flashing at 5 second intervals means that the release lever is open the power voltage is insufficient or an incorrect programme has been selected se...

Страница 8: ...possible to programme these distances manually one by one so you can make the gate door stop in exactly the places you want To simplify the programming there is a completely automatic programming pha...

Страница 9: ...earch 4 1 PROGRAMMING As an alternative to the initial limits search which only takes place if the gearmotor has never been installed before it is possible at any time to activate an automatic limit s...

Страница 10: ...key on the card to move the gate door in the closing phase until the mechanical stop is reached 3 If you want besides the CLOSE key you can also press the key to accelerate movement 4 When the gate do...

Страница 11: ...er than B 1 Set the dip switches as indicated in this way the manual search for distance A is selected 2 Press the OPEN or CLOSE keys to open or close the gate door until it reaches the point wanted 3...

Страница 12: ...say 25 seconds turn dip switches 5 4 and 1 ON the sum of 16 8 1 25 3 Once you have selected the time you can proceed to memorisation Pause Time for automatic manoeuvres is memorised with this procedu...

Страница 13: ...econds of preflashing Switch 3 On Condominium function In the Condominium functioning mode once an opening manoeuvre has started for instance with a Step by Step pulse this movement cannot be interrup...

Страница 14: ...he effect the adjustment has on the trimmer it is best to wait for movement to start and for the gate door to reach standard speed Also ensure for safety reasons that if the clutch intervenes three ti...

Страница 15: ...he connector on the unit 8 MAINTENANCE The card being electronic needs no particular maintenance However check periodically at least twice a year the perfect efficiency and adjustment of the device th...