4.2 - ELECTRICAL CABLES PREPARATION
To prepare all connection cables, proceed as follows.
a)
- Observe
fig. 7
to understand how the various devices should be con-
nected to the control unit and the terminals to be used for each con-
nection.
b)
- Observe
fig. 7
to understand how to position the electrical cables in
the environment. Then, draw a similar diagram on paper, adapting it
to the specific needs of your system.
Note
- This diagram will be use-
ful, both to guide the excavation of the routes for the cable ducting,
and for drawing up a complete list of the cables required.
c)
- Read
Table 6
to determine the type of cables to use; then use the
diagram you just drew and the environmental measurements to
determine the length of each individual cable.
Caution! - Each cable
must not exceed the maximum length indicated in Table 6.
Warnings:
• Ducting and raceways are used to protect the electrical cables from
damage due to accidental impacts.
• When laying the ducting, also take into account that due to possible
deposits of water in the routing ducts, the ducting might create con-
densation in the control unit, with consequent damage to the electronic
circuits.
• Place the ends of the ducting in the vicinity of the points provided for
affixing the devices.
7
a
e
f
b
c
d
g
c
g
f
e
B
C
B
D
D
C
A
TABLE 6 - Technical specifications of electric cables (fig. 7)
Connection
Cable type
(minimum gauge values)
Max allowable length
A
- Electricity supply line
Cable 3 x 1.5 mm
2
30 m
(note 1)
B
- STOP input
Cable 2 x 0.5 mm
2
20 m
(note 2)
C
- OPEN input
Cable 2 x 0.5 mm
2
20 m
(note 2)
D
- Motors M1 and M2 output
Cable 3 x 1 mm
2
10 m
Note 1
- You may use a cable which is longer than 30 m, provided it has a larger gauge (for example, 3 x 2.5 mm
2
) and that it is equipped
with, in the vicinity of the automation, safety grounding.
Note 2
- For the cables for the STOP and OPEN inputs, you can also use a single cable with more internal conductors, to group multiple con-
nections: for example, inputs STOP and OPEN can be connected to the KS100 selector switch with a cable of 4 x 0.5 mm
2
.
CAUTION! – The cables used must be suited to the installation environment; for example a cable type H03VV-F for indoor envi-
ronments, or type H07RN-F for outdoor environments, is recommended.
Содержание MhouseKit WG2W
Страница 2: ......
Страница 6: ...English 4 English 2 729 45 392 100 85 4 B D A C 5 3 150 min 150 max 1 F B E D C A G ...
Страница 11: ...English English 9 17 A B C D 15 600 34 11 12 13 14 16 ...
Страница 12: ...English 10 English 18 E F 19 I G H 20 KS100 WG1SK M2 WG1SK M1 brown yellow green blue brown yellow green blue ...
Страница 42: ...Italiano 4 Italiano 2 729 45 392 100 85 4 B D A C 5 3 150 min 150 maxi 1 F B E D C A G ...
Страница 47: ...Italiano Italiano 9 17 A B C D 15 600 34 11 12 13 14 16 ...
Страница 78: ...Français 4 Français 2 729 45 392 100 85 4 B D A C 5 3 150 min 150 maxi 1 B E D C A G F ...
Страница 83: ...Français Français 9 16 17 A B C D 15 600 34 11 12 13 14 ...
Страница 84: ...Français 10 Français 18 E F 19 I G H 20 KS100 WG1SK M2 WG1SK M1 marron jaune vert bleu marron jaune vert bleu ...
Страница 114: ...Polski 4 Polski 2 729 45 392 100 85 4 B D A C 5 3 150 min 150 maks 1 F B E D C A G ...
Страница 119: ...Polski Polski 9 17 A B C D 15 600 34 11 12 13 14 16 ...
Страница 147: ......