10.5 - TROUBLESHOOTING
Table 15
contains instructions to help you solve malfunctions or errors
that may occur during the installation stage or in case of failure.
10.6 - DIAGNOSTICS AND SIGNALS
A few devices give out special signals that allow you to recognise the
operating status or possible malfunctions.
10.6.1 - Photocells
The photocells include LEDs that allow you to check their operational
state at any time. For the led “
A
” (
fig. 48
) see
Table 16
. For the led “
B
”
(
fig. 48
) see
Table 18
.
10.6.2 - Flashing indicator
The flashing indicators include LEDs that allow you to check their opera-
tional state at any time. For the led “
A
” (
fig. 48
) see
Table 17
. For the led
“
B
” (
fig. 48
) see
Table 18
.
During the manoeuvre the flashing indicator flashes once every second.
When something is wrong the flashes are more frequent (every half sec-
ond); the light flashes twice with a second’s pause between flashes, see
Table 19
.
to associate that command.
Holding the two transmitters, position yourself within the operating range
of the automation and perform the following operations:
01.
Press the key on the NEW radio transmitter and hold it down for at
least 5s, then release it.
02.
Press the button on the OLD radio transmitter 3 times slowly.
03.
Press the key on the NEW radio transmitter once slowly.
At this point, the NEW radio transmitter will be recognised by the control
unit, and take on the characteristics that the OLD one had.
If there are other transmitters to memorise, repeat all the above steps for
each new transmitter.
10.4.4 - Deleting a radio transmitter
If you have available only one radio transmitter, use this operation to
delete it.
If the transmitter is memorised in Mode 1, one deletion phase is sufficient
and at point 3 you may press any key. If the transmitter is stored in mode
2, a deletion phase is required for each memorised key.
01.
Press the P2 key (
fig. 48
) on the control unit and hold it down.
02.
Wait until the LED P2 (
fig. 48
) lights up, within three seconds.
03.
Press the key of the radio transmitter to be deleted for at least three
seconds. If cancellation was successful the LED P2 will flash quick-
ly five times. If LED P2 emits 1 slow flash, the deletion phase was
unsuccessful because the transmitter is not memorised.
04.
If there are other transmitters to delete, keeping P2 depressed, repeat
step 3 within another 10 seconds; otherwise, the deletion phase will
stop automatically.
10.4.5 - Deleting all memorised radio transmitters
This operation deletes all memorised transmitters.
01.
Press the P2 key (
fig. 48
) on the control unit and hold it down.
02.
Wait until the P2 LED (
fig. 48
) lights up, then wait until it goes off,
then wait until it has flashed 3 times.
03.
Release P2 exactly during the third flash.
04.
Wait for around 4s for the deletion phase to finish; during this time the
LED P2 will flash very quickly.
If the procedure is successful, after a few moments the P2 LED will flash
slowly 5 times.
TABLE 14
1 time
“Open” command
Commands the automation as described in table 9 (Open function)
2 times
“Pedestrian opening” command
Causes partial opening of one or two leaves as described in table 9 (Pedestrian Opening)
3 times
“Open Only” command
Causes the leaves to open (open - stop - open etc.)
4 times
“Close Only” command
Causes the leaves to close (close - stop - close etc.)
5 times
“Stop” command
Stops the manoeuvre
6 times
“Apartment block open” command
The command has no effect on opening, when closing the command causes the movement to
reverse, that is, opens the leaves
7 times
“High priority open” command
Command executes even with automation locked
8 times
“Pedestrian opening 2” command
Causes partial opening of leaf M2, equal to halfway
9 times
“Pedestrian opening 3” command
Causes partial opening of both the leaves, equal to halfway
10 times
“Open and Lock Automation”
command
Causes an opening manoeuvre and when this is complete, the automation is locked; the control
unit will not accept any command other than “High priority open” and “Release” of the automation
11 times
“Close and Lock Automation”
command
Causes a closure manoeuvre and when this is complete, the automation is locked; the control
unit will not accept any command other than “High priority open” and “Release” of the automation
12 times
“Lock Automation” command
Causes a halt of the manoeuvre and locks the automation; the control unit will not accept any
command other than “High priority open” and “Release” of the automation.
13 times
“Release Automation” command
Causes automation release and reset to normal operation
Содержание MhouseKit WG2W
Страница 2: ......
Страница 6: ...English 4 English 2 729 45 392 100 85 4 B D A C 5 3 150 min 150 max 1 F B E D C A G ...
Страница 11: ...English English 9 17 A B C D 15 600 34 11 12 13 14 16 ...
Страница 12: ...English 10 English 18 E F 19 I G H 20 KS100 WG1SK M2 WG1SK M1 brown yellow green blue brown yellow green blue ...
Страница 42: ...Italiano 4 Italiano 2 729 45 392 100 85 4 B D A C 5 3 150 min 150 maxi 1 F B E D C A G ...
Страница 47: ...Italiano Italiano 9 17 A B C D 15 600 34 11 12 13 14 16 ...
Страница 78: ...Français 4 Français 2 729 45 392 100 85 4 B D A C 5 3 150 min 150 maxi 1 B E D C A G F ...
Страница 83: ...Français Français 9 16 17 A B C D 15 600 34 11 12 13 14 ...
Страница 84: ...Français 10 Français 18 E F 19 I G H 20 KS100 WG1SK M2 WG1SK M1 marron jaune vert bleu marron jaune vert bleu ...
Страница 114: ...Polski 4 Polski 2 729 45 392 100 85 4 B D A C 5 3 150 min 150 maks 1 F B E D C A G ...
Страница 119: ...Polski Polski 9 17 A B C D 15 600 34 11 12 13 14 16 ...
Страница 147: ......